STR-DN610 - Sony Audio Service Manual (repair manual). Page 9

Read Sony STR-DN610 Service Manual online

STR-DN610
9
HISTORY MODE
The state that the set is used is memorized.
Procedure:
1.  While pressing the [INPUT MODE] and [MUSIC] buttons, 
press the [
?/1
] button to turn on the power and “HISTORY” 
is displayed.
2.  Each time the [ r ] [ R ] key of remote commander is pressed, 
the item is switched in order as follows.
Items
Display
Protector count
COUNT xx
Total single power on time
xxxxxHxx
Sound fi eld
SND FLD
Input function
FUNCTION
Input mode
INP MODE
Digital select
DIG IN
Stream information
STREAM
Signal confi guration
CO xxxxx
Headphones
HP xxx
Volume
VOL xx
Bass
BASS xxx
Treble
TREB xxx
Level FL/FR
F xxxxxx
Level SL/SR
S xxxxxx
Level CT/SW
CW xxxxxx
Level SBL/SBR
B xxxxxx
Total power on time
xxxxx Hxx
Muting
MUTE xxx
Power on counter
(Rebox test mode)
REBx.xxxx
Protector Type
PROT xxxx
Temperature when protect
TEM xxxx
DCAC FACTORY TEST MODE
DCAC Factory Test mode have two stages:
1.  DCAC DSP Data Line Checking
2.  DCAC board Checking
Factory Test System Setup
1.  When power off:
 
Press the three buttons [MEMORY/ENTER] + [MOVIE] +  
[
?/1
].
 “DCAC
[]
FTM” appears.
 
Afterward, press the [DISPLAY] to start DCAC factory test 
mode.
1. DCAC DSP Data Line Checking
After press the [DISPLAY], DCAC Factory test mode will start, 
below display will show:
“DCAC
[][][]
x”  x=1, 2, 3, 4
If there is error happen, below display will show:
“ERR
[]
SD0x” x=1 
t D1501 or R1530 problem
 x=2 
t D1502 problem
 x=3 
t D1503 problem
 x=4 
t D1504 problem
2. DCAC board Checking
Connect front left speaker of the receiver and AUTO CAL micro-
phone. Turn [MASTER VOLUME] jog, there will be test tone 
sound output from front left speaker, and the display will change 
accordingly.
“AD
[]
-
[]
xxx” 
xxx=0 to 255 (depends on loudness of test tone)
Note:
When the value reaches more than 222, the test tone will muted 
(for production line checking). Thus, the AD value will drop to 0. 
To check the AD value again, power off the receiver and re-enter 
the test mode.
DSP Data Line
Check
Start
Pass
Pass
Auto Cal Mic
Check
END
SPK Front Left
DCAC MIC
Receiver
Page of 72