STR-DH540 - Sony Audio Service Manual (repair manual). Page 4

Read Sony STR-DH540 Service Manual online

STR-DH540
4
MODEL IDENTIFICATION
–BACK PANEL–
 
   
Part No.
Model
Part No.
US, Canadian
4-442-874-0[]
AEP, UK
4-442-874-1[]
Australian
4-442-874-2[]
UNLEADED  SOLDER
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with 
the lead free mark due to their particular size)
 : LEAD  FREE  MARK
Unleaded solder has the following characteristics.
• 
Unleaded solder melts at a temperature about 40 °C higher than
ordinary solder.
 
Ordinary soldering irons can be used but the iron tip has to be 
applied to the solder joint for a slightly longer time.
 
Soldering irons using a temperature regulator should be set to 
about 350 °C.
Caution:  The printed pattern (copper foil) may peel away if the 
heated tip is applied for too long, so be careful!
• Strong 
viscosity
 
Unleaded solder is more viscous (sticky, less prone to fl ow) than
ordinary solder so use caution not to let solder bridges occur 
such as on IC pins, etc.
• 
Usable with ordinary solder
 
It is best to use only unleaded solder but unleaded solder may 
also be added to ordinary solder.
SECTION  1
SERVICING  NOTES
NOTE  OF  REPLACING  THE  IC3506  AND  IC4100  ON  
THE  DIGITAL  BOARD
IC3506 and IC4100 on the DIGITAL board cannot exchange with 
single. When these parts on the DIGITAL board are damaged, 
exchange the entire mounted board.
NOTE  OF  REPLACING  THE  COMPLETE  DIGITAL 
 
BOARD
When the COMPLETE DIGITAL BOARD is exchanged, please 
perform the following procedures.
a) RESET MODEL AND DESTINATION SETTING
1.  Press the [?/1] button to turn on the main power.
2.  While pressing [DISPLAY] button, press and release the 
[A.F.D.], [MOVIE], [MUSIC] button in order, the message 
“SPECIALIZE” appears.
3.  Press the [ 
M ] or [ m ] key of the remote commander, the 
message “<SPECIAL>” appears.
4.  Press the [
] key of the remote commander to enter the 
Special Menu List.
5.  Press the [ 
M ] or [ m ] key of the remote commander to 
select “MODEL&AREA” then press [
] key of the remote 
commander.
6. Press 
the 
[ 
M ] or [ m ] key of the remote commander to select 
“MD.DST.UNFIX”, press [
] key of the remote commander 
for resetting the model and destination.
b) FIX MODEL AND DESTINATION 
Please refer to “FIX MODEL AND DESTINATION MODE” in 
page 12 for fi xing the model and destination of set.
Ver. 1.3
Note: Refer to SUPPLEMENT-1 for adding SERVICING NOTES 
(TROUBLESHOOTING)
Page of 84
Display

Click on the first or last page to see other STR-DH540 service manuals if exist.