STR-DG500, STR-DG600 - Sony Audio Service Manual (repair manual). Page 3

Read Sony STR-DG500 / STR-DG600 Service Manual online

3
STR-DG500/DG600
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  
0
  OR  DOTTED  LINE
WITH  MARK  
0
  ON  THE  SCHEMATIC  DIAGRAMS  AND  IN
THE  PARTS  LIST  ARE  CRITICAL  TO  SAFE  OPERATION.
REPLACE  THESE  COMPONENTS  WITH  SONY  PARTS  WHOSE
PART  NUMBERS  APPEAR  AS  SHOWN  IN  THIS  MANUAL  OR
IN  SUPPLEMENTS  PUBLISHED  BY  SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
 À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 
0
 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE  DES PIÈCES
SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT.
NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES
SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL
OU DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
1.5 k
0.15 
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
SAFETY  CHECK-OUT (US MODEL)
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indica-
tion is 0.75 V, so analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex-
amples of a passive VOM that is suitable. Nearly all battery
operated digital multimeters that have a 2 V AC range are suit-
able.  (See Fig. A)
Fig. A.  Using an AC voltmeter to check AC leakage.
MODEL IDENTIFICATION
— BACK PANEL —
Part No.
MODEL
PART No.
DG500: US
2-661-146-0s
DG500: CND
2-661-146-1s
DG500: AEP, UK
2-661-146-2s
DG500: TH
2-661-146-3s
DG500: AUS
2-661-146-4s
DG500: TW
2-661-146-5s
DG500: KR
2-661-146-6s
DG500: E2
2-661-146-7s
DG600: US
2-661-147-0s
DG600: CND
2-661-147-1s
DG600: TH
2-661-147-3s
DG600: E2
2-661-147-5s
DG600: MY, SP
2-661-147-9s
DG500: MY, SP
2-686-376-0s
• Abbreviation
CND : Canadian model
AUS : Australian model
TW : Taiwan model
KR : Korea model
E2
: 120 V AC area in E model
MY : Malaysia model
SP
: Singapore model
TH : Thai model
Ver. 1.1
Page of 83
Display

Click on the first or last page to see other STR-DG500 / STR-DG600 service manuals if exist.