STR-DE400 - Sony Audio Service Manual (repair manual). Page 11

Read Sony STR-DE400 Service Manual online

11
STR-DE400
SWAP ALL MODE
Procedure:
1. While depressing the   PRESET TUNING –  and the  A.F.D.
buttons simultaneously, press the power  ?/1  button to turn
on the main power.
2. “SWP.ALL” appears. (No change while displayed.)
ADCC FACTORY TEST MODE
ADCC Factory Test mode have two stages:
1. ADCC DSP Data Line Checking
2. ADCC AUTO CAL MIC board Checking
Factory Test System Setup
1. When power off :
Press the three buttons   <  +  DISPLAY  +  ?/1  .
(If it doesn’t operate, please press  DISPLAY  again afetr 2
seconds.)
Afterward, press the  DIMMER  to start DCAC factory test
mode.
1. ADCC DSP Data Line Checking
After press the  DIMMER  , DCAC Factory test mode will start,
below display will show:
“DCAC[][][]x”      x = 1, 2, 3
If there is error happen, below display will show:
“ERR[]SD0x”
x = 1 
→ D1112 or R1198 or C1523 problem
x = 2 
→ D1113 problem
x = 3 
→ D1114 problem
2. ADCC AUTO CAL MIC board Checking
Connect front left speaker of the receiver and AUTO CAL
microphone. Turn  MASTER VOLUME  jog, there will be test tone
sound output from front left speaker, and the display will change
accordingly.
“AD[]-[]xxx”
xxx = 0 to 255 (depends on loudness of test tone)
DSP Data Line
Check
Start
Pass
Pass
Auto Cal Mic
Check
END
SPK Front Left
ADCC MIC
Receiver
Page of 52
Display

Click on the first or last page to see other STR-DE400 service manuals if exist.