STR-DB798 - Sony Audio Service Manual (repair manual). Page 12

Read Sony STR-DB798 Service Manual online

12
STR-DB798
BIAS  ADJUSTMENT
Condition:
input signal: no signal (no load)
volume:
minimum
Connection
Procedure:
1. Connect a digital voltmeter to the CN432 (CN482, CN532,
CN582, CN632, CN682, CN732) on the MAIN board.
2. Press the
I
/1
button to turn on the main power.
3. Adjust the RV431 (RV481, RV531, RV581, RV631, RV681,
RV731) on the MAIN board so that the digital voltmeter
reading is 15
±
2 mV.
Note:
When the adjusting voltage is higher than 15
±
2 mV, adjust the
voltage to the minimum voltage.
Adjustment and Connection Loacation:
+
digital voltmeter
CN432 (CN482, 532, 582, 632, 682, 732) pin 
1
CN432 (CN482, 532, 582, 632, 682, 732) pin 
2
CN432
CN482
CN532
CN582
CN632
CN682
RV581
RV531
RV631
RV681
RV481
RV731
CN732
2 1
2 1
2 1
2 1
2 1
1
2
2 1
RV431
– MAIN Board (Component Side) –
SECTION 5
ELECTRICAL  ADJUSTMENTS
Page of 95
Display