NOTE : The preset data will be erased when this test mode is used. Therefore, take down the data before setting this mode and preset the
data again after completing operations in this mode.
2. Display Tube Check and KEY Check mode
1. Turn OFF the power.
2. While pressing 1 and  AUTO-BETICAL SELECT  together, turn ON  !  .
3. While continuously pressing 1 and  AUTO-BETICAL SELECT  together, check the following.
Indication test pattern
The display changes every 1 sec.
4. Release 1 and  AUTO-BETICAL SELECT  . The KEY CHECK mode will be set.
5. All key numbers will be displayed.
Key Number : 25
6. Each time the key is pressed, the key number will be counted down.
Each key will be counted only once, at the first time.
7. When all keys have been pressed, the process will end.
NOTE : As contents of the Factory Preset will be written into memory after completing this check mode, delete contents of memory
according to 4. Forced RESET.
3. Entering the Factory Preset (In case perform just to write memory of the Factory Preset.)
1. Turn OFF the power.
2. While pressing 3 and  AUTO-BETICAL SELECT  together, turn ON  ! .
4. Forced RESET (Used to delete the contents of Factory Preset when it is written into the preset memory.)
Clears all the RAMs and sets the initial state
1. Turn OFF the power.
2. While pressing 5 and  AUTO-BETICAL SELECT  together, turn ON  ! .
3. When “All clear” is indicated on the fluorescent display tube, it means that “Forced Reset” has been completed.
Microcomputer version indication (1 sec) 
t All light up “7F” t Dot area only “60” t Dot area only “7E”
Dot area only “5F” 
T Dot area only “3D”
T
T
1
 7F
2
 60
3
 7E
4
 3D
5
 5F