SECTION 1
SERVICING NOTES
UNLEADED SOLDER
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size)
: LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40 °C higher
• Unleaded solder melts at a temperature about 40 °C higher
than ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350 °C.
Caution: The printed pattern (copper foil) may peel away if
about 350 °C.
Caution: The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful!
• Strong
viscosity
Unleaded solder is more viscous (sticky, less prone to fl ow)
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
•
Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
also be added to ordinary solder.
NOTE OF REPAIRING THE BOARDS
When boards other than the MAIN board installed by this unit are
defective, individual electrical parts that the mount is done cannot
be replaced.
Replace the mounted board, or replace the whole parts including
an applicable board.
When boards other than the MAIN board installed by this unit are
defective, individual electrical parts that the mount is done cannot
be replaced.
Replace the mounted board, or replace the whole parts including
an applicable board.
NOTE THE CN401, IC001, IC012, IC905 AND IC906
ON THE MAIN BOARD REPLACING
CN401, IC001, IC012, IC905 and IC906 on the MAIN board can-
not replace with single. When these parts are damaged, replace the
complete mounted board.
ON THE MAIN BOARD REPLACING
CN401, IC001, IC012, IC905 and IC906 on the MAIN board can-
not replace with single. When these parts are damaged, replace the
complete mounted board.
NOTE OF BAFFLE REPLACING
The washers (twelve places) may be attached to the baffl e of this
unit.
When replacing baffl e, it is not necessary to newly attach the wash-
ers.
Please attach a new baffl e in the state where there are no washers.
The washers (twelve places) may be attached to the baffl e of this
unit.
When replacing baffl e, it is not necessary to newly attach the wash-
ers.
Please attach a new baffl e in the state where there are no washers.
When replacing baffle,
twelve washers are not necessary.
twelve washers are not necessary.
baffle (inside)
NOTE OF WiFi MODULE REPLACING
When the WiFi module is replaced, the MAC address and DTCP-
IP ID have been changed.
Print the page 7 and 9, and pass it to the customer with the repaired
unit when you return the customer the repaired unit.
When the WiFi module is replaced, the MAC address and DTCP-
IP ID have been changed.
Print the page 7 and 9, and pass it to the customer with the repaired
unit when you return the customer the repaired unit.
PROCESSING OF REPLACING THE WiFi MODULE
When replacing the WiFi module (Ref. No. WIFI1), peel the de-
vice ID label stuck on the bottom side of the unit, and stick on the
new device ID label enclosed with the new WiFi module (Ref. No.
WIFI1).
When replacing the WiFi module (Ref. No. WIFI1), peel the de-
vice ID label stuck on the bottom side of the unit, and stick on the
new device ID label enclosed with the new WiFi module (Ref. No.
WIFI1).
1 Peel the device
ID
ID
label.
– Bottom view –
Model number label
indication
indication
2 Stick on the new
device ID label.
Device ID: XXXXXXXXXXXX
MAC Address: XX-XX-XX-XX-XX-XX