SRS-D511 - Sony Audio Service Manual (repair manual). Page 2

Read Sony SRS-D511 Service Manual online

2
SRS-D511
TABLE OF CONTENTS
Specifications ............................................................................ 1
1.
GENERAL
................................................................... 3
2.
DIAGRAMS
2-1.
Schematic Diagram – Amp Section– ............................... 4
2-2.
Printed Wiring Boards– Amp Section – .......................... 5
2-3.
Schematic Diagram – Control Section– .......................... 6
2-4.
Printed Wiring Boards – Control Section– ...................... 7
3.
EXPLODED VIEWS
3-1.
Subwoofer Section .......................................................... 8
3-2.
Control Box, Satellite Speaker Section ........................... 9
4.
ELECTRICAL PARTS LIST
.................................. 10
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following
safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth Ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples
of a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  0  OR  DOTTED  LINE
WITH  MARK 
0 ON  THE  SCHEMATIC  DIAGRAMS  AND  IN  THE
PARTS  LIST  ARE  CRITICAL  TO  SAFE  OPERATION.  REPLACE
THESE  COMPONENTS  WITH  SONY  PARTS  WHOSE  PART
NUMBERS  APPEAR  AS  SHOWN  IN  THIS  MANUAL  OR  IN
SUPPLEMENTS  PUBLISHED  BY  SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
 À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE  DES PIÈCES
SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT.
NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES
SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL
OU DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
To Exposed Metal 
Parts on Set
0.15 
µF
1.5 k
AC
Voltmeter
(0.75 V)
Earth Ground
Fig. A.  Using an AC voltmeter to check AC leakage.
Page of 14
Display