SRF-M80 - Sony Audio Service Manual (repair manual). Page 6

Read Sony SRF-M80 Service Manual online

6
SRF-M80
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
RV1
999 kHz
AM VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
531 kHz
2.5 
± 0.1 V
Confirmation
1602 kHz
8.6 
± 0.3 V
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
621 kHz
CT1
1,404 kHz
FM VCO VOLTAGE CONFIRMATION
Frequency Display
Reading on Digital Voltmeter
87.5 MHz
8.3 
± 0.3 V
108 MHz
13.6 
± 0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3
98.0 MHz
Adjustment Location: MAIN board (See page 7)
FM STEREO ADJUSTMENT
Setting:
BAND button: FM
1. Connect the frequency counter to TP (FM ST) and TP (+B) as
shown the figure below.
2. Tune the set to 87.5 MHz.
3. Adjust RV2 for 75.9 to 76.1 kHz reading on the frequency
counter.
Adjustment Location: MAIN board (See page 7)
0 dB=1 
µ
V
[AM]
Setting:
BAND button : AM
[FM/TV]
Setting:
BAND button: FM
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM antenna in FM adjustment.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
16 
i
 jack (J1)
digital voltmeter
TP (VT)
TP (FM GND)
100 k
MAIN board
SECTION  3
ELECTRICAL  ADJUSTMENTS
set
MAIN board
TP (FM IN)
MAIN board
TP (FM GND)
0.01 
µ
F
Carrier frequency : 87.5 MHz
Modulation
: no modulation
Output level
: 0.1 V (100 dB)
FM RF SSG
33 k
+
+
MAIN board
TP (FM ST)
TP (+B)
TP (FM GND)
frequency counter
µ
F/50 V
digital voltmeter
TP (VT)
TP (AM GND)
100 k
MAIN board
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: 
as low as possible
+
level meter
i
 jack (J1)
set
MAIN board
TP (FM IN)
MAIN board
TP (FM GND)
16 
0.01 
µ
F
Page of 17