SRF-H5 - Sony Audio Service Manual (repair manual). Page 8

Read Sony SRF-H5 Service Manual online

– 8 –
TUNER SECTION
• POWER switch
: ON
• VOL
: MAX
 AM Section
BAND switch
: AM
 FM Section
BAND switch
: FM
SECTION 5
ELECTRICAL ADJUSTMENTS
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
22.5kHz frequency deviation 
by 400Hz signal.
Output level : as low as possible
FM WIRE 
ANTENNA input
0.01  F
µ
set
16
speaker output
level meter
AM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
520kHz
CT1-3
1,750kHz < 1,650kHz >
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L7
620kHz
CT1-4
1,400kHz
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L8
86.5MHz
CT1-1
109.5MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
86.5MHz
CT1-2
109.5MHz
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
no mark : COM
<         > : AEP, Australian model
Adjustment Location :  MAIN board (See page 10)
Page of 16
Display

Click on the first or last page to see other SRF-H5 service manuals if exist.