SRF-46 - Sony Audio Service Manual (repair manual). Page 4

Read Sony SRF-46 Service Manual online

FM FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for maximum reading on level meter
L6
86.5 MHz (Except Italian)
87.35 MHz (Italian)
CT1
109.5 MHz (Except Italian)
108.25 MHz (Italian)
– 4 –
SECTION  4
ELECTRICAL  ADJUSTMENT
Setting:
SENS switch: DX
FM  STEREO  (38 kHz) Adjustment
Setting:
SENS switch: DX
Procedure:
1. Connect 10 
µ
F Capacitor to TP (38 kHz) and TP (GND).
2. Connect the frequency counter to TP (VCO).
3. Adjust L4 for 38 kHz 
±
 20 Hz reading on the frequency counter.
Connection:
22.5 kHz frequency deviation
by 400 Hz signal.
Output level: as low as possible
FM RF signal
generator
0.01 
µ
F
TP (RF IN)
• Repeat the procedures in each adjustment several times, and the
frequency coverage adjustments should be finaly done by the
timmer capacitors.
2nd OSC Adjustment
Setting:
SENS switch: DX
Procedure:
1. Connect the frequency counter to TP (OSC).
2. Adjust L2 for 56.75 MHz 
±
 0.25 MHz reading on the frequency
counter.
Connection:
frequency counter
µ
F/50 V
TP (OSC) (IC1 
 PIN)
+
+
• Adjustment Location:  MAIN board
— Component Side—
S1
S3
L4
L2
L6
CT1
CV1
L4: FM STEREO
(38 kHz) ADJUSTMENT
L2: 2nd OSC
 ADJUSTMENT
CT1:  FM FREQUENCY
COVERAGE
ADJUSTMENT
L6:  FM FREQUENCY
COVERAGE
ADJUSTMENT
f
 min
f
 min
— Conductor Side—
frequency counter
µ
F/50 V
TP (VCO) (IC1 
 PIN)
+
+
TP
(RF IN)
TP
(VCO)
TP
(OSC)
IC1
TP
(GND)
TP
(38 kHz)
+
10 
µ
F
16 V
set
headphone jack ( 
2
)
level meter
16 
+
Page of 9
Display