SDP-E800 - Sony Audio Service Manual (repair manual). Page 13

Read Sony SDP-E800 Service Manual online

— 13 —
3. Initialization
After executing the test mode, be sure to perform initialization.
When the  POWER  button is pressed while pressing the  DIGITAL 1
button and  DIGITAL 3  button, “All Clear!” is displayed on the
fluorescent display tube and all internal settings are initialized.
[Fluorenscent Display Tube All Lit]
With the power OFF, while pressing the  DIGITAL 3  button and  
button togher, press the  POWER  button to turn ON the power.
The fluorenscent display tube all lit modewill be set.
SECTION  3
TEST MODE
[Self-Diagnosis and Test Mode]
This unit is provided with a “self-diagnosis and self-recovery func-
tion” which detects DSP errors and automatically recovers the unit,
and a test mode for performing operation checks during repairs.
1. Main Functions
1. DSP Error Messages
2. Various operation check mode
3. Initialization
2. Entering the Test Mode
While pressing the  DIGITAL 2  button and  ANALOG  button
simultaneously in the power OFF state, press the  POWER  button.
1. DSP Error Messages
When errors occur in the DSP, they are displayed on the fluorescent
display tube.
(Refer to Table 1 for the error messages displayed.)
Table-1:
2. Operation Check Mode
• During the operation check mode, functions can be set by press-
ing the corresponding button. (See Table-2.)
• When a button other than those displayed in Table 2 is pressed,
press the  POWER  button to exit the check mode.
Table-2:
Button
Function
Fluorescent
Display Tube
Display
DIGITAL1
OPT-1
(L-FL, R-FR)
Like normal operations, Lch is output to
Lch and Rch to Rch.
DIGITAL2
OPT-2
(L-SL, R-SR)
Outputs the Lch DIGITAL-2 input signal
to the REAR Lch and the Rch to the REAR
Rch.
DIGITAL3
OPT-3
(L-C, R-SW)
Outputs the Lch DIGITAL-3 input signal
to the CENTER and the Rch only to the
WOOFER.
ANALOG
COAX
(L, R-ALL)
Outputs the Lch DIGITAL 1 COAXIAL
input signal to the FRONT Lch, REAR
Lch, CENTER, and the Rch to the FRONT
Rch, REAR Rch, and CENTER.
Possible cause
1 Failed in initial
booting
(BOOT ERROR)
2 DSP does not
operate
(RPLY ERROR)
3 Communication
port malfunction
(HREQ ERROR)
4 No reply from
DSP
(VRFY ERROR)
Mostly due to faulty connection (soldering)
between DSP and microprocessor
Faulty DSP clock (X102 and onwards), faulty
DSP part, etc.
Overrunning of DSP due to heat, micropro-
cessor bugging, or IC701 (PLL board PLL) is
faulty
Faulty DSP part, or faulty microprocessor part,
etc.
Cause of error
(Display)
Button name
Fluorenscent display tube state
DIGITAL 1
DIGITAL 2
DIGITAL 3
ANALOG
All lit
Partial lighting 1
Partial lighting 2
OFF
When the other buttons are pressed, press the  POWER button to
exit the mode.
Partial lighting 1
Partial lighting 2
[Key Check Mode]
When the  POWER  button is pressed while pressing the  DIGITAL 1
button and  ANALOG  button, “KEY CHECK:12 KEYS” is dis-
played on the fluorescent display tube and the key check mode is
set.
When the  POWER  button is pressed during this mode, the number
at “12 KEYS” is counted down. When all other buttons are pressed,
the number stops at “00 KEYS” (Note: The number is not counted
down when buttons already pressed once are pressed again.).
To exit the mode, press the  POWER  button and turn OFF the
power.