Read Sony SDP-E800 Service Manual online
— 13 —
3. Initialization
After executing the test mode, be sure to perform initialization.
When the POWER button is pressed while pressing the DIGITAL 1
button and DIGITAL 3 button, “All Clear!” is displayed on the
fluorescent display tube and all internal settings are initialized.
button and DIGITAL 3 button, “All Clear!” is displayed on the
fluorescent display tube and all internal settings are initialized.
[Fluorenscent Display Tube All Lit]
With the power OFF, while pressing the DIGITAL 3 button and
∨
button togher, press the POWER button to turn ON the power.
The fluorenscent display tube all lit modewill be set.
The fluorenscent display tube all lit modewill be set.
SECTION 3
TEST MODE
[Self-Diagnosis and Test Mode]
This unit is provided with a “self-diagnosis and self-recovery func-
tion” which detects DSP errors and automatically recovers the unit,
and a test mode for performing operation checks during repairs.
tion” which detects DSP errors and automatically recovers the unit,
and a test mode for performing operation checks during repairs.
1. Main Functions
1. DSP Error Messages
2. Various operation check mode
3. Initialization
2. Various operation check mode
3. Initialization
2. Entering the Test Mode
While pressing the DIGITAL 2 button and ANALOG button
simultaneously in the power OFF state, press the POWER button.
simultaneously in the power OFF state, press the POWER button.
1. DSP Error Messages
When errors occur in the DSP, they are displayed on the fluorescent
display tube.
(Refer to Table 1 for the error messages displayed.)
display tube.
(Refer to Table 1 for the error messages displayed.)
Table-1:
2. Operation Check Mode
• During the operation check mode, functions can be set by press-
ing the corresponding button. (See Table-2.)
• When a button other than those displayed in Table 2 is pressed,
press the POWER button to exit the check mode.
Table-2:
Button
Function
Fluorescent
Display Tube
Display
Display Tube
Display
DIGITAL1
OPT-1
(L-FL, R-FR)
(L-FL, R-FR)
Like normal operations, Lch is output to
Lch and Rch to Rch.
Lch and Rch to Rch.
DIGITAL2
OPT-2
(L-SL, R-SR)
(L-SL, R-SR)
Outputs the Lch DIGITAL-2 input signal
to the REAR Lch and the Rch to the REAR
Rch.
to the REAR Lch and the Rch to the REAR
Rch.
DIGITAL3
OPT-3
(L-C, R-SW)
(L-C, R-SW)
Outputs the Lch DIGITAL-3 input signal
to the CENTER and the Rch only to the
WOOFER.
to the CENTER and the Rch only to the
WOOFER.
ANALOG
COAX
(L, R-ALL)
(L, R-ALL)
Outputs the Lch DIGITAL 1 COAXIAL
input signal to the FRONT Lch, REAR
Lch, CENTER, and the Rch to the FRONT
Rch, REAR Rch, and CENTER.
input signal to the FRONT Lch, REAR
Lch, CENTER, and the Rch to the FRONT
Rch, REAR Rch, and CENTER.
Possible cause
1 Failed in initial
booting
(BOOT ERROR)
(BOOT ERROR)
2 DSP does not
operate
(RPLY ERROR)
(RPLY ERROR)
3 Communication
port malfunction
(HREQ ERROR)
(HREQ ERROR)
4 No reply from
DSP
(VRFY ERROR)
(VRFY ERROR)
Mostly due to faulty connection (soldering)
between DSP and microprocessor
between DSP and microprocessor
Faulty DSP clock (X102 and onwards), faulty
DSP part, etc.
DSP part, etc.
Overrunning of DSP due to heat, micropro-
cessor bugging, or IC701 (PLL board PLL) is
faulty
cessor bugging, or IC701 (PLL board PLL) is
faulty
Faulty DSP part, or faulty microprocessor part,
etc.
etc.
Cause of error
(Display)
Button name
Fluorenscent display tube state
DIGITAL 1
DIGITAL 2
DIGITAL 3
ANALOG
All lit
Partial lighting 1
Partial lighting 2
OFF
When the other buttons are pressed, press the POWER button to
exit the mode.
exit the mode.
Partial lighting 1
Partial lighting 2
[Key Check Mode]
When the POWER button is pressed while pressing the DIGITAL 1
button and ANALOG button, “KEY CHECK:12 KEYS” is dis-
played on the fluorescent display tube and the key check mode is
set.
When the POWER button is pressed during this mode, the number
at “12 KEYS” is counted down. When all other buttons are pressed,
the number stops at “00 KEYS” (Note: The number is not counted
down when buttons already pressed once are pressed again.).
To exit the mode, press the POWER button and turn OFF the
power.
button and ANALOG button, “KEY CHECK:12 KEYS” is dis-
played on the fluorescent display tube and the key check mode is
set.
When the POWER button is pressed during this mode, the number
at “12 KEYS” is counted down. When all other buttons are pressed,
the number stops at “00 KEYS” (Note: The number is not counted
down when buttons already pressed once are pressed again.).
To exit the mode, press the POWER button and turn OFF the
power.
Click on the first or last page to see other SDP-E800 service manuals if exist.