SCD-XA3000ES - Sony Audio Service Manual (repair manual). Page 20

Read Sony SCD-XA3000ES Service Manual online

20
SCD-XA3000ES
Measured Items
Specified value
RF AVRG (ADJ)
8Ch to ABh
VC AVRG (ADJ)
1F7h to09h
FE  AVRG (ADJ)
(1) CD
1EEh to 12h
(2) SACD
1F1h to 0Fh
TE AVRG (ADJ)
1E2h to 1Eh
TRVS PP (ADJ)
45h to 73h
FCS GAIN
10h to 60h
TRK GAIN
10h to 60h
(1) CD
C1
20 or less
ERROR RATE
C2
0
(2) SACD
PI1 NUM
100 or less
PI1 FRAME
5 or less
PSP AMPLITUDE (SACD only)
1000 to 4000
1-LAST TRK SEK
3500 or less
Hexadecimal (hex) display 9 bit data
FF
011111111 (+255) 
FE
011111110 (+254) 
(+) Side
(-) Side
MAX
01
000000001 (+1) 
00
000000000 (0) 
1FF
111111111 (-1) 
101
100000001 (-255) 
100
100000000 (-256) 
Hexadecimal (hex) display 8 bit data
7F
01111111 (+127) 
7E
01111110 (+126) 
01
00000001 (+1) 
00
00000000 (0) 
02
00000010 (+2) 
FF
11111111 (-1) 
FE
11111110 (-2) 
81
10000001 (-127) 
80
10000000 (-128) 
MIN
0
Specified Value:
Specified value used for OK/NG judgment when executing 92. SET CHECK
tAUTO CHECK SP?
Note:
 The specified values attached with “h” are hexadecimal numbers, and others are decimal numbers.
RF, VC, FE, and TE measured values are hexadecimal data with positive and negative signs. When comparing the measured
value with the specified value, refer to the following.
Page of 88
Display