SA-VE325, SA-WMS325, SS-CN325, SS-V325 - Sony Audio Service Manual (repair manual)

sa-ve325, sa-wms325, ss-cn325, ss-v325 service manual
Model
SA-VE325 SA-WMS325 SS-CN325 SS-V325
Pages
17
Size
1.53 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / BRAZIL
File
sa-ve325-sa-wms325-ss-cn325-ss-v325.pdf
Date

Read Sony SA-VE325 / SA-WMS325 / SS-CN325 / SS-V325 Service Manual online

MANUAL DE SERVIÇO
 
Sistema de Caixas Acústicas Microssatélite
Brazilian Model
Ver 1.1  2001.07
ESPECIFICAÇÕES
SA-VE325/WMS325/
SS-CN325/V325
 SA-VE325
Active Subwoofer (SA-WMS325) 
a
Center Speaker (SS-CN325) 
a
Front and Rear Speakers (SS-V325) 
a
SA-WMS325
SS-V325
SS-CN325
SS-V325 (caixa frontal e traseira)
Sistema                                     Full range,tipo bassreflex
magneticamente blindadas
Unidade de alto-falantes           5.5 × 11 cm, tipo cone  
Impedância nominal                  8 ohms
Potência Máxima                     100 watts
Nível de sensibilidade              87 dB (1 W, 1 m)
Faixa de freqüência                  90 Hz - 20,000 Hz
Dimensões (LxAxP)                Aprox. 70 × 152 × 126mm
(incluindo o quadro telar)
Peso                                          Aprox. 830 g 
SS-CN325 (caixa central)
Sistema                                      Full range × 2,
magneticamente blindada
Unidade de alto falante             5.5 × 11 cm, tipo cone 
Tipo de alto-falante                  Bass reflex
Impedância nominal                 8 ohms
Potência máxima                      120 watts
Nível de sensibilidade              89 dB (1 W, 1 m)
Faixa de freqüência                  90 Hz - 20,000 Hz
Dimensões (LxAxP)                Aprox. 300x78x126mm 
(incluindo o quadro telar)
Peso                                          Aprox. 1600 g 
SA-WMS325 (subwoofer)
Sistema                                     Subwoofer Ativo,
magneticamente blindado
Unidade do alto-falante            Woofer: 16 cm tipo cone
 
Tipo do gabinete                      SAW avançado
Faixa de freqüência de reprodução
28 Hz - 200 Hz
Seção do Amplificador
 Potência de saída de reprodução
75 W (8 ohms, 20 Hz -
20 kHz, 0.8% THD)
Entradas
LINE IN (tomada RCA)
SPEAKER IN (terminal de entrada)
Saídas
LINE OUT (tomada RCA)
SPEAKER OUT (terminal de entrada)
Geral
 Alimentação:                           CA 127 V/220V, 60 Hz
 Consumo                                  70 W 
 Dimensões (LxAxP)                Aprox. 205x380x389 mm
(incluindo quadro telar)
Peso                                           Aprox. 10.3 kg  
Acessorios fornecidos
Pés de apoio (20)
Cabo RCA para conexão de Áudio  (1)
Cabos de conexão para caixas acústicas
          satélites traseiras, 10 m    (2)
Cabos de conexão para caixas acústicas
           satélites frontais e central, 3.5 m  (3)
Cabos de conexão para conectar o Subwoofer
           ao amplificador (opção B ) 2.5 m  (2)
Projetos e especificações técnicas sujeitos à alteração
sem prévio aviso.
9-890-250-01
2
SA-VE325/WMS325/SS-CN325/V325
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  
0
  OR  DOTTED
LINE  WITH  MARK  
0
  ON  THE  SCHEMATIC  DIAGRAMS
AND  IN  THE  PARTS  LIST  ARE  CRITICAL  TO  SAFE
OPERATION.  REPLACE  THESE  COMPONENTS  WITH
SONY  PARTS  WHOSE  PART  NUMBERS  APPEAR  AS
SHOWN  IN  THIS  MANUAL  OR  IN  SUPPLEMENTS  PUB-
LISHED  BY  SONY.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs,
screws, and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The “limit” indication is 0.75
V, so analog meters must have an accurate low-voltage scale.
The Simpson 250 and Sanwa SH-63Trd are examples of a pas-
sive VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2 V AC range are suitable.  (See Fig. A)
Fig. A.
Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
3
SA-VE325/WMS325/SS-CN325/V325
SEÇÃO  1
DIAGRAMAS
1-1. NOTAS PARA PLACA DE CIRCUITO IMPRESSO E DIAGRAMA ESQUEMÁTICO
Note on Printed Wiring Board:
: Pattern from the side which enables seeing.
Note on Schematic Diagram:
• All capacitors are in 
µ
F unless otherwise noted.  pF: 
µµ
F
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
2
: nonflammable resistor.
C
: panel designation.
A
: B+ Line.
B
: B– Line.
• Voltages are dc with respect to ground under no-signal
conditions.
• Voltages are dc with respect to ground in service mode.
no mark : MUSIC MODE
(
) : MOVIE MODE
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Signal path.
F
: AUDIO
Note:
The components identi-
fied by mark 
0
 or dotted
line with mark 
0
 are criti-
cal for safety.
Replace only with part
number specified.
Note:
Les composants identifiés par
une marque 
0
 sont critiques
pour la sécurité.
Ne les remplacer que par une
pièce por tant le numéro
spécifié.
 Localização das Placas
(SA-WMS325)
placa PRINCIPAL
placa de POWER 
placa AUTO POWER 
placa de CHAVE POWER 
placa de CONTROLE
placa de CONECTOR
placa de MODO
4
SA-VE325/WMS325/SS-CN325/V325
D101
E-5
D102
E-5
D103
D-5
D104
D-5
D301
B-2
D302
B-2
D303
D-2
D304
D-2
D305
F-4
D306
H-3
D501
H-4
D502
D-3
D503
D-3
D701
F-5
D702
F-5
D703
F-4
D704
G-4
IC101
D-5
IC102
B-5
IC103
B-4
IC104
F-5
IC701
G-5
Q101
B-5
Q102
A-5
Q103
A-4
Q104
A-4
Q301
D-2
Q302
C-2
Q303
C-2
Q304
C-3
Q305
C-3
Q306
D-2
Q307
D-3
Q308
F-2
Q309
E-2
Q310
F-2
Q311
F-2
Q701
F-5
Q702
F-5
Q703
H-5
Q704
H-5
Q705
H-5
1-2. PLACA DE CIRCUITO IMPRESSO – Seção PRINCIPAL (SA-WMS325) –
 See page 3 for Circuit Boards Location.
• Semiconductor
Location
Ref. No.
Location
MAIN BOARD  
J101
OUT
OUT
IN
LINE
SPEAKER
TM101
IN
L
R
+
+
+
+
POWER SAVE
AUTO
OFF
S701
(11)
11
1-680-777-
T501
POWER
TRANSFORMER
SP1
A
CONNECTOR BOARD
CN202
E
AUTO POWER
BOARD
CN604
B
POWER BOARD
CN401
C
AUTO POWER
BOARD
CN605
D
POWER SWITCH
BOARD
CN801
A
B
C
D
E
F
G
H
I
J
K
L
1
2
3
4
5
6
IC102
IC103
IC101
IC104
IC701
(Page 7)
(Page 7)
(Page 8)
(Page 8)
(Page 8)
Page of 17
Display

Download Sony SA-VE325 / SA-WMS325 / SS-CN325 / SS-V325 Service Manual (Repair Manual)

Here you can read online and download Sony SA-VE325 / SA-WMS325 / SS-CN325 / SS-V325 Service Manual in PDF. SA-VE325 / SA-WMS325 / SS-CN325 / SS-V325 service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony SA-VE325 / SA-WMS325 / SS-CN325 / SS-V325 Audio. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.