PMC-DR45L - Sony Audio Service Manual (repair manual). Page 21

Read Sony PMC-DR45L Service Manual online

– 21 –
TRAVERSE Check
This check is to be done when the optical pick-up block is replaced.
Check Procedure:
1. Connect the oscilloscope to test point TP (VC) and TP (TE) on
MAIN board. Insert disk (YEDS-18).
2. Put the set into test mode.
3. Optical pick-up setting to the center by > or . button
pushing.
4. Press u button.
5. Check that the oscilloscope traverse waveform is symmetrical,
as shown in the figure below.
6. Release test mode after adjustment is completed.
Notes on Check
1. Perform the traverse check in the CD test mode.
After check, be sure to exit the test mode.
2. Perform check in the order given.
3. Use the disc (YEDS-18, Parts No. 3-702-101-01) only when so
indicated.
Before check
Put the set into test mode and perform the following checks.
Repair if there are any problems.
• Sled Motor Check
Press >, . keys and confirm that the Optical pick-up moves
smoothly from the innermost to outermost circumference and back
smoothly and with no catching or abnormal noises.
(Cancellation of BTL mute)
> : Optical pick-up moves to the outer circumference.
. : Optical pick-up moves to the inner circumference.
• Focus Search Check
1. Press the CD u key. (Focus search operation is performed
continuously.)
2. Look at the Optical pick-up objective lens and confirm that it
moves up and down smoothly, with no catching or abnormal
noises.
3. Press x button.
Confirm that focus search operation stops. If it does not, press
x button again longer.
Setting the Test Mode
1. Turn the power on.
2. Solder the TEST-C pattern on the TOP board to short.
Releasing the Test Mode
1. Turn the power off and remove the solder.
2. Turn the power on again.
Connecting Location:
5-3. CD SECTION
Focus Bias Check
This check is to be done when the optical block replaced.
Check Procedure:
1. Connect the oscilloscope to test point TP (VC) and TP (RF) on
MAIN board. Insert disk (YEDS-18).
2. Put the set into test mode.
3. Optical pick-up setting to the center by + or – button pushing.
4. Press the u button and press the DISPLAY ENTER button.
(Tracking servo ON)
5. Check that the oscilloscope waveform is as shown in the figure
below (eye pattern).
A good eye pattern means that the diamond shape (    ) in the
center of the waveform can be clearly distinguished.
6. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
VOLT/DIV: 0.1 V 
TIME/DIV: 1 ms
(with the 10:1 probe in use.)
1.2-1.8Vp-p
VOLT/DIV : 50mV
TIME/DIV  : 500 ns
(With the 10:1 probe in use)
1.1- 1.3 Vp-p
Ver 1.1
– TOP BOARD –
TEST-C
Page of 71
Display

Click on the first or last page to see other PMC-DR45L service manuals if exist.