NWZ-A726, NWZ-A726B, NWZ-A728, NWZ-A728B, NWZ-A729 - Sony Audio Service Manual (repair manual). Page 13

Read Sony NWZ-A726 / NWZ-A726B / NWZ-A728 / NWZ-A728B / NWZ-A729 Service Manual online

13
NWZ-A726/A726B/A728/A728B/A729
4-2-9.  Sound pressure regulation level check
“1 kHz 0 dBs L-ch/R-ch VOLUME: 30” audio signal is output-
ted.
Checking method:
1.  Enter the test mode.
2. Press 
the 
[
v
]/[
V
] key to select the “AUDIO”, and press the [
B
key to enter the minor item.
3.  Press the [
v
]/[
V
] key to select the “SPCHK”.
4.  Press the [
u
] key, “1 kHz 0 dBs L-ch/R-ch VOLUME: 30”  
audio signal is outputted.
   
liquid crystal display
AUDIO SPCHK
1kHz 0dBs L/Rch
HPOUT [ VOL: 30 ]
START
5.  Press the [BACK] key, return to minor item selection screen.
4-3. Video
   
liquid crystal display
MPTAPP MENU
 POWER
 AUDIO
 
VIDEO — LCD
 OTHER
 CLESTE
 DAC
 SHUTDOWN
 EXITTEST
4-3-1.  LCD display check
Liquid crystal display is checked.
Checking method:
1.  Enter the test mode.
2. Press 
the 
[
v
]/[
V
] key to select the “VIDEO”, and press the [
B
key to select the “LCD”.
3. Press 
the 
[
u
] key, all black is displayed on the liquid crystal 
display.
4.  In this state, each time the [OPTION] key is pressed, the screen 
display changes in the following order.
    All black (default) 
→ All red → All green → All blue → All 
white 
→ Color bar → Maximum drawing size confi rmation 
→ diagonal gradation (red) → diagonal gradation (green) → 
diagonal gradation (blue) 
→ diagonal gradation (white)
    Maximum drawing size confi rmation:
    All blue (All sides are red) is displayed. Whether red in all 
sides is seen is confi rmed.
5.  In this state, each time the [VOL –] key is pressed, LCD back 
light brightness min/max/middle switch is performed.
6.  Press the [BACK] key, return to minor item selection screen.
4-4. Other
   
liquid crystal display
MPTAPP MENU
 POWER
 AUDIO
 VIDEO
 OTHER 
CLOCK
 CLESTE 
KEY
 DAC 
KETYNUM
 SHUTDOWN 
FORMAT
 EXITTEST DEST
  
SPSET
  
FWVER
  
NCAPCHK
4-4-1. Clock check
The movement of an internal clock is confi rmed.
Checking method:
1.  Enter the test mode.
2. Press 
the 
[
v
]/[
V
] key to select the “OTHER”, and press the [
B
key to enter the minor item.
3.  Press the [
v
]/[
V
] key to select the “CLOCK”.
4.  Press the [
u
] key, date and time are displayed.
   
liquid crystal display
OTHER CLOCK
XX, XX XX XXXX
##:##:##.######
START
    XX, XX XX XXXX  : Date
   ##:##:##.###### 
: Time
    “START” changes into “OK” if the movement of an internal 
clock is confi rmed. 
5.  Press the [BACK] key, return to minor item selection screen.
Page of 52
Display

Click on the first or last page to see other NWZ-A726 / NWZ-A726B / NWZ-A728 / NWZ-A728B / NWZ-A729 service manuals if exist.