NW-E5 - Sony Audio Service Manual (repair manual). Page 9

Read Sony NW-E5 Service Manual online

9
NW-E5
SECTION 4
TEST MODE
Setting the Test Mode
To enter the test mode, two methods are available :
1. Entering method with key input.
Turn the HOLD switch to ON. While holding down the Bx key, press the following keys in the following order :
VOLUME + 
t VOLUME – t VOLUME – t VOLUME + t VOLUME – t MEGA BASS t MEGA BASS t DISPLAY
Note : Push each key for less than 3 seconds.
2. Entering method by shorting the test point.
Solder brige the test point SL701 (TEST) on the main board and turn on the power.
Releasing the TEST mode
1. When test mode was entered with key input, turn off the power supply.
2. When test mode was entered by shorting the test point, turn off the power supply and open the solder brige of SL701 (TEST) on the main
board.
Test mode
Short : Test mode
Open : Normal mode
(
    )
1
4
regulated
DC power supply
Connecting cable
supplied with the set
USB Connector
(1-784-009-11 or 1-779-676-11)
Set
Battery terminal
CN701
(USB Connector)
regulated
DC power supply
LCD
Check
Ver. /
destination
display
All display
lit
(+)
(–)
All display
off
Flash memory
bad block
check
Bx
Bx
(+)
(–)
(+)
(–)
Destination
setting
Contrast
adjustment
(–)
Low voltage
check
(–)
Bx
Bx
(–)
High DC
detection
check
Low DC
detection
check
(+)
Supply 0.9V DC to battery 
terminal and press (–) key.
Supply 1.24V DC to battery 
terminal and 7V DC to USB 
connector and press (+) key.
Supply 1.24V DC to battery 
terminal and 4V DC to USB 
connector and press (+) key.
Configuration of Test Mode
The test mode has the configuration given below.
Bx
: Play/stop key
(+)
: VOLUME + key
(–)
: VOLUME – key
Connection
R805
R804
R814
R806
R812 R813
R811
R810
R702
JC704
TP3
SL701
(TEST)
TP701
MAIN BOARD   (SIDE A)
Page of 26