NW-E305, NW-E307 - Sony Audio Service Manual (repair manual). Page 14

Read Sony NW-E305 / NW-E307 Service Manual online

14
NW-E305/E307
SECTION 3
TEST MODE
STANDING PROCEDURE
Procedure 1: In HOLD state, while pushing  Nx  button  and
 
 / MENU  button, push [REST].
When the test mode is set, the LCD display appears
as shown below.
Procedure 2: After starting up test mode, the following contents
can be checked.
TEST MODE
512M   1.00.01   G14
The place of destination
FW version
NAND FLASH RAM capacity 
BUTTON NAME
DESCRIPTION
 /MENU
Push the  
 /MENU  button, so displayed Fmax/
Fmin for FM broadcast received frequency.
A display change as shown below whenever the
 
 /MENU  button is pushed.
 FM[P__}76.0MHz
 FM[P__}TV 3CH
DISP/FM
Displayed “TUNER OFF”.
u (AMS+)
Displayed charge mode (100mA/500mA).
A display change as shown below whenever the
 u (AMS+)  button is pushed.
Charge Mode 500m
Charge Mode 100m
U (AMS–)
Display Charge ON/OFF.
Change a display as shown below whenever the
 U (AMS–)  button is pushed.
 Charge On
 Charge Off
HOLD
Change a display as shown below whenever in the
state of HOLD ON.
• LCD lights up to a checkered pattern.
• All LCD lights on.
In the state of HOLD OFF.
• Displayed “HOLD KEY OFF”
VOL i
Displayed “Beep: ON”
VOL I
Displayed “Beep: OFF”
REP/SOUND
Push the  REP/SOUND  button, so “Initialized” is
displayed.
Initialized. (Turn to the factory preset state, time,
volume setting and so on.) The music data and files
in the memory are not changed.
Nx
“Check all key” is displayed, so the key test mode
is activated, when the  Nx  button is pressed.
Push all button around.
Escape a test mode if the  Nx  button is pressed
at last.
Page of 39
Display