NW-A805, NW-A806, NW-A808, NWZ-A815, NWZ-A816, NWZ-A818 - Sony Audio Service Manual (repair manual). Page 16

Read Sony NW-A805 / NW-A806 / NW-A808 / NWZ-A815 / NWZ-A816 / NWZ-A818 Service Manual online

16
NW-A805/A806/A808/NWZ-A815/A816/A818
4-2-9. Sound pressure regulation level check
“1 kHz 0 dBs L-ch/R-ch VOLUME: 30” audio signal is outputted.
Checking method:
1. Enter the test mode.
2. Press the  
v
 / 
V
  key to select the “AUDIO”, and press the 
B
key to enter the minor item.
3. Press the 
v
 / 
V
 key to select the “SPCHK”.
4. Press the 
u
  key,  “1 kHz 0 dBs L-ch/R-ch VOLUME: 30”
audio signal is outputted.
liquid crystal display
AUDIO SPCHK
1kHz 0dBs L/Rch
HPOUT [ VOL: 30 ]
START
5. Press the [BACK]
 
key, return to minor item selection screen.
4-3. Video
liquid crystal display
MPTAPP MENU
POWER
AUDIO
VIDEO
LCD
OTHER
SHUTDOWN
EXITTEST
4-3-1. LCD display check
Liquid crystal display is checked.
Checking method:
1. Enter the test mode.
2. Press the  
v
 / 
V
  key to select the “VIDEO”, and press the  
B
key to select the “LCD”.
3. Press the u key, all black is displayed on the liquid crystal
display.
4. In this state, each time the [OPTION]
 
key is pressed, the screen
display changes in the following order.
All black (default) 
→ All red → All green → All blue → All
white 
→ Color bar → Maximum drawing size confirmation
Maximum drawing size confirmation:
All blue (All sides are red) is displayed. Whether red in all
sides is seen is confirmed.
4. In this state, each time the [VOL ---]
 
key is pressed, LCD back
light brightness min/max/middle switch is performed.
5. Press the [BACK]
 
key, return to minor item selection screen.
4-4. Other
liquid crystal display
MPTAPP MENU
POWER
AUDIO
VIDEO
OTHER
CLOCK
SHUTDOWN
KEY
EXITTEST
FORMAT
DEST
SPSET
FWVER
NCAPCHK
4-4-1. Clock check
The movement of an internal clock is confirmed.
Checking method:
1. Enter the test mode.
2. Press the 
v
 / 
V
 key to select the “OTHER”, and press the  
B
key to enter the minor item.
3. Press the 
v
 / 
V
 key to select the “CLOCK”.
4. Press the 
u
 key, date and time are displayed.
liquid crystal display
OTHER CLOCK
XX, XX XX XXXX
##:##:##.######
START
XX, XX XX XXXX
: Date
##:##:##.######
: Time
“START” changes into “OK” if the movement of an internal
clock is confirmed.
5. Press the [BACK]
 
key, return to minor item selection screen.
Page of 52
Display

Click on the first or last page to see other NW-A805 / NW-A806 / NW-A808 / NWZ-A815 / NWZ-A816 / NWZ-A818 service manuals if exist.