NW-A25, NW-A25HN, NW-A26HN, NW-A27HN - Sony Audio Service Manual (repair manual). Page 35

Read Sony NW-A25 / NW-A25HN / NW-A26HN / NW-A27HN Service Manual online

NW-A25/A25HN/A26HN/A27HN
35
4-12-2.  Microphone gain (R-ch) adjustment (GAIN-R)
This mode can be adjust the microphone gain (R-ch).
Checking method:
1.  Enter the test mode.
 
(Refer to “1. SETTING THE TEST MODE” on page 23)
2.  Press the [
v
]/[
V
] keys to select the “NC”, and press the [
B
] key 
to enter the minor item.
3.  Press the [
v
]/[
V
] keys to select the “GAIN-R”.
4.  Press the [
u
] key, microphone gain (R-ch) is displayed.
 
(Displayed values in the following fi gure are example)
NC GAIN-Rch
27
MODE
0
CVOL
f4   a6
Screen display
Microphone gain
NC mode
Noise Cancellation volume
(displayed for NC mode 0/1/2 only)
5.  In this state, each time the [
b
]/[
B
] keys are pressed, micro-
phone gain (R-ch) is changed.
6.  In this state, each time the [HOLD] switch is slide from ON 
to OFF, the NC mode changes into “-1 (NC off)/0 (airplane)/1 
(train)/2 (offi ce)”.
7.  When NC mode is in the state of “0”, “1” or “2”, [VOL +]/
[VOL –] keys is pressed, noise cancellation volume is changes.
8.  Save the microphone gain by pressing the [
u
] key and return 
to minor item.
 
If do not save it, press the [BACK] key, return to minor item.
4-12-3.  
Noise canceling headphone detection 
(NCHPCHK)
This mode can be check the detection of noise canceling head-
phone.
Note: Noise canceling 
headphone is
 necessary to execute this mode.
Checking method:
1.  Connect noise canceling headphone with the WALKMAN.
2.  Enter the test mode.
 
(Refer to “1. SETTING THE TEST MODE” on page 23)
3. Press 
the 
[
v
]/[
V
] keys to select the “NC”, and press the [
B
] key 
to enter the minor item.
4.  Press the [
v
]/[
V
] keys to select the “NCHPCHK”.
5. Press 
the 
[
u
] key, the detection of noise canceling headphone 
is executed.
Connected Noican HP
Screen display
6.  Press the [BACK] key, return to minor item selection screen.
4-13. Shutdown 
(SHUTDOWN)
Function that power supply of set can be turned off without ending 
static test mode.
Procedure:
1.  Enter the test mode.
 
(Refer to “1. SETTING THE TEST MODE” on page 23)
2. Press 
the 
[
v
]/[
V
] keys to select the “SHUTDOWN”, and press 
the [
B
] key to select the “SURE ?”.
3. Press 
the 
[
u
] key, turn the power off while having entered the 
test mode.
Page of 44
Display