CHARGE CONTROL IC9001 outputs status signals shown in Table.4-4 while charging to PLD IC8001.
Table.4-4 Status signal
IC9001 Pin-67 [XCHG_STAT1]
IC9001 Pin-68 [XCHG_STAT2]
Status
L
L
Charging Suspend
When transferring data from PC
When playing
When detecting the abnormal temperature
Etc.
L
Open
When charging
Open
L
When the charging operation terminates
Open
Open
Error Status (Timer Fault)
Battery Driving
Table.4-5 Monitoring the charging operation by PLD IC8001
IC8001 Pin-61 [CHG_STAT1]
IC8001 Pin-63 [XCHG_STAT2]
Status
H
L
Charging Suspend
When transferring data from PC
When playing
When detecting the abnormal temperature
Etc.
H
H
When charging
L
L
When the charging operation terminates
L
H
Error Status (Timer Fault)
Battery Driving
Table.4-6 Charging Current
Power Source
Pre-charging
(Until BATT voltage becomes 3[V])
(Until BATT voltage becomes 3[V])
Constant-Current Charging
Remark
AC Power Adapter
Approx. 50mA
3.0[V] to 3.3[V]: Approx. 350mA
3.3[V] to 3.6[V]: Approx. 425mA
Over 3.6[V]: Approx. 500mA
3.3[V] to 3.6[V]: Approx. 425mA
Over 3.6[V]: Approx. 500mA
-
USB
Approx. 50mA
3.0[V] to 3.6[V]: Approx. 350mA
Over 3.6[V]: Approx. 425mA
Over 3.6[V]: Approx. 425mA
Varies depending on conditions.
Note:
The actual charging current of USB charge varies depending on the system conditions. It will be as follows.
[Each VBUS limit current] – [Current consumed by the system] = [Actual charging current]