NW-A1000, NW-A1200 - Sony Audio Service Manual (repair manual). Page 25

Read Sony NW-A1000 / NW-A1200 Service Manual online

Copying is strictly prohibited 
 
25 
 
CHARGE CONTROL IC9001 outputs status signals shown in Table.4-4 while charging to PLD IC8001. 
 
Table.4-4 Status signal 
IC9001 Pin-67 [XCHG_STAT1] 
IC9001 Pin-68 [XCHG_STAT2] 
Status 
Charging Suspend 
 
When transferring data from PC 
 
When playing 
 
When detecting the abnormal temperature 
Etc. 
Open 
When charging 
Open 
When the charging operation terminates 
Open 
Open 
 
Error Status (Timer Fault) 
 
Battery Driving 
 
Table.4-5 Monitoring the charging operation by PLD IC8001 
IC8001 Pin-61 [CHG_STAT1] 
IC8001 Pin-63 [XCHG_STAT2] 
Status 
Charging Suspend 
 
When transferring data from PC 
 
When playing 
 
When detecting the abnormal temperature 
Etc. 
When charging 
When the charging operation terminates 
 
Error Status (Timer Fault) 
 
Battery Driving 
 
 
Table.4-6 Charging Current 
Power Source 
Pre-charging 
(Until BATT voltage becomes 3[V]) 
Constant-Current Charging 
Remark 
AC Power Adapter 
Approx. 50mA 
3.0[V] to 3.3[V]: Approx. 350mA 
3.3[V] to 3.6[V]: Approx. 425mA 
Over 3.6[V]: Approx. 500mA 
USB 
Approx. 50mA 
3.0[V] to 3.6[V]: Approx. 350mA 
Over 3.6[V]: Approx. 425mA 
Varies depending on conditions. 
 
Note: 
 
The actual charging current of USB charge varies depending on the system conditions. It will be as follows.   
[Each VBUS limit current] – [Current consumed by the system] = [Actual charging current] 