MHC-VX3 (serv.man2) - Sony Audio Service Manual (repair manual). Page 11

Read Sony MHC-VX3 (serv.man2) Service Manual online

11
[AMS Test  Mode]
• This mode is used for checking the AMS operations of the tape deck.
JIG
7-819-039-12 Alignment tape, AMS-110A
Procedure:
1.
Press the  
1/u  button to turn the unit ON.
2.
Set the tape (AMS-110A).
3.
Press the three buttons  
p  ,  ENTER/NEXT  , and  DISC 3  button simultaneously.
4.
“TEST MODE” is displayed on the fluorescent display tube.
5.
Press the  FUNCTION  button and switch the function to the deck with the tape (AMS-110A).
6.
Press the  CD SYNC  button. “AMS CHECK” is displayed on the fluorescent display tube and the tape is rewound.
7.
AMS starts in the normal direction. If the AMS count is 2 at shut down, proceed to step 8.
“NG” is displayed at other times, and the deck stops.
8.
AMS starts in the opposite direction. If the AMS count is 2 at shut down again, “OK” is displayed.
“NG” is displayed at other times.
Note: The  
p  button of CD section will become effective and the aging of CD section will stop sometime, if the buttons described in step 3
are not pressed simultaneously. In that case, press  
^  button and operate the CD section.