3-1. Circuit operation (Standby mode of Power saving mode) 
14 
1: AC voltage input 
4: System controller  
    boots up. 
2: Power supply board 
    outputs 13.5V for 
    SYSCON booting. 
MICOM 
  + DSP 
Page 41 
3: EVER+3.3V outputs 
    from D/D Converter 
    (IC002) 
Repair tips: 
Original standby mode is 
“demonstration” mode. 
In this mode, FL tube and  
Speaker LED operates for 
demonstration. 
By pressing DISPLAY button 
while the set turn off, the  
mode can be shifted to 
“Power saving” and “clock”. 
Repair tips: 
EVER+3.3V output can be 
checked at ARAGON board  
connecter terminal. 
(CN304 pin1 and 2) 
Repair tips: 
13.5V output can be checked 
 at connecter terminal 
(CN001 pin1 and 3) 
Page of 29