IOP DATA RECORDING AND DISPLAY WHEN PICKUP AND NON-VOLATILE MEMORY (IC171 OF BD BOARD)
ARE REPLACED
The IOP value labeled on the pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need to look
at the value on the label of the optical pick-up. When replacing the pick-up or non-volatile memory (IC171 of BD board), record the IOP
value on the pick-up according to the following procedure.
Record Precedure:
1. While pressing the  ENTER/YES  button and  
π  button, connect the power plug to the outlet, and release the  ENTER/YES  button and
π  button.
2. “TEMP CHECK” will be displayed. Press the  MENU/NO  button to display “Check”.
3. Rotate the  – 
˜ +  knob to display “[Service]”, and press the  ENTER/YES  button.
4. Rotate the  – 
˜ +  knob to display “lop.Write”, and press the  ENTER/YES  button.
5. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
6. Input the IOP value written on the optical pick-up.
To select the number : Rotate the  – 
˜ +  knob.
To select the digit
: Press the  CD SYNC/MD WM SYNC  button.
7. When the  ENTER/YES  button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
8. As the adjustment results are recorded for the step 6 value. Leave it as it is and press the  ENTER/YES  button.
9. “Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop
Write”.
10.Press the  
1/u  button to complete. “Standby” will be displayed.
Display Precedure:
1. While pressing the  ENTER/YES  button and  
π  button, connect the power plug to the outlet, and release the  ENTER/YES  button and
π  button.
2. “TEMP CHECK” will be displayed. Press the  MENU/NO  button to display “Check”.
3. Rotate the  – 
˜ +  knob to display “[Service]”, and press the  ENTER/YES  button.
4. Rotate the  – 
˜ +  knob to display “lop.Read”.
5. “@@.@/##.#” is displayed and the recorded contents are displayed.
@@.@ : indicates the Iop value labeled on the pick-up.
##.#
: indicates the Iop value after adjustment
6. To end, press the  CD SYNC/MD WM SYNC  button or  MENU/NO  button to display “Iop Read”. Then press the  
1/u  button to display
“Standby”.