MDS-SD1 - Sony Audio Service Manual (repair manual). Page 28

Read Sony MDS-SD1 Service Manual online

– 28 –
KMS
260A
27X40
B0825
N
Iop = 82.5 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
)
7. Then, rotate the  – 
˜ +  knob and display “LDPWR CHECK”.
8. Press the  ENTER/YES  button once and display “LD 0.9 mW $
”. Check that the reading of the laser power meter become
0.85 to 0.91 mW.
9. Press the  ENTER/YES  button once more and display “LD 7.0
mW $ 
”. Check that the reading the laser power meter and
digital volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value :
Laser power meter reading : 7.0 ± 0.1 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%
(Optical pick-up label)
10. Press the  MENU/NO  button and display “LDPWR CHECK”
and stop the laser emission.
(The  MENU/NO  button is effective at all times to stop the
laser emission.)
11. Rotate the  – 
˜ +  knob to display “Iop.Write”.
12. Press the  ENTER/YES  button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the  ENTER/
YES  button to display “Measu=@@@.@” (@ is an arbitrary
number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Rotate the  – 
˜ +  knob.
To select the digit : Press the  CD SYNC/MD WM SYNC  but-
ton.
14. When the  ENTER/YES  button is pressed, “Complete!” will
be displayed momentarily. The value will be recorded in the
non-volatile memory and the display will become “Iop Write”.
Note 1: After step 4, each time the  ENTER/YES  button is pressed,
the display will be switched between “LD 0.7 mW $ 
”,
“LD 6.2 mW $ 
”, and “LD Wp               $ 
”. Nothing
needs to be performed here.
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying IOP Information”.)
5-11. TRAVERSE  ADJUSTMENT
Connection :
Adjusting Procedure :
1. Connect an oscilloscope to CN110 pin 3 (TE) and CN110 pin
1 (VC) of the BD board.
2. Load a disc (any available on the market). (Refer to Note 1.)
3. Press the  
)/±  button and move the optical pick-up out-
side the pit.
4. Rotate the  – 
˜ +  knob and display “EF MO ADJUST”.
5. Press the  ENTER/YES  button and display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Rotate the  – 
˜ +  knob so that the waveform of the oscillo-
scope becomes the specified value.
(When the  – 
˜ +  knob is rotated, the   of “EFB=  ” changes
and the waveform changes.) In this adjustment, waveform var-
ies at intervals of approx. 2%. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the  ENTER/YES  button and save the result of adjustment
to the non-volatile memory (“EFB = 
 SAVE” will be displayed
for a moment. Then “EFB = 
 MO-W” will be displayed).
8. Rotate the  – 
˜ +  knob so that the waveform of the oscillo-
scope becomes the specified value.
(When the  – 
˜ +  knob is rotated, the   of “EFB-  ” changes
and the waveform changes.) In this adjustment, waveform var-
ies at intervals of approx. 2%. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Write power traverse adjustment)
(Traverse Waveform)
9. Press the  ENTER/YES  button, and save the adjustment results
in the non-volatile memory. (“EFB = 
 SAVE” will be displayed
for a moment.)
10. “EFB = 
 MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and servo
is imposed.
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Oscilloscope
BD board
CN110 pin 
3
 (TE)
CN110 pin 
1
 (VC)
VC
A
B
Specification A = B
VC
A
B
Specification A = B
Page of 65