MDS-PC2 - Sony Audio Service Manual (repair manual). Page 10

Read Sony MDS-PC2 Service Manual online

10
Fig. 1 Reading the Test Mode Display
(During recording and stop)
RTs@@c##c**
Fluorescent display tube display
@@ : Cause of retry
##
: Number of retries
**
: Number of retry errors
Fig. 2 Reading the Test Mode Display
(During playback)
@@####**$$
Fluorescent display tube display
@@ : Parts No. (name of area named on TOC)
##
: Cluster
**
: Sector
$$
: Track mode (Track information such as copyright infor-
mation of each part)
Reading the Retry Cause Display
RETRY CAUSE DISPLAY MODE
• In this test mode, the causes for retry of the unit during recording can be displayed on the fluorescent indicator tube. During playback, the
“track mode” for obtaining track information will be set.
This is useful for locating the faulty part of the unit.
• The following will be displayed :
During recording and stop : Retry cause, number of retries, and number of retry errors.
During playback
: Information such as type of disc played, part played, copyright.
These are displayed in hexadecimal.
Precedure:
1. Load a recordable disc whose contents can be erased into the unit.
2. For discs with no disc name, set the name display using the remote commander. (The time display is set after some time. Leave as it is if
desired.)
3. Press the  
p  button immediately. Wait for about 10 seconds while pressing the button. (The  AMS  knob can be pressed instead of the  YES
button for the same results.)
4. The fluorescent display tube displays “RTs@@c##e**”.
5. Press the  
r  button to start recording. Then press the  ^  button and start recording.
6. To check the “track mode”, press the  
^  button to start play.
7. To exit the test mode, press the  
1/u  button. If the test mode cannot be exited, refer to “Forced Reset” on page 8.
} Address (Physical address on disc)
Hexadecimal
Bit
Binary
Higher Bits
Lower Bits
8
4
2
1
8
4
2
1
b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
When track jump (shock) is detected
When ADER was counted more than five times
continuously
When ADIP address is not continuous
When DIN unlock is detected
When not in focus
When ABCD signal level exceeds the specified range
When CLV is unlocked
When access operation is not performed normally
Hexa-
decimal
shock
ader5
Discontinuous address
DIN unlock
FCS incorrect
IVR rec error
CLV unlock
Access fault
Cause of Retry
Occurring conditions
01
02
04
08
10
20
40
80
Reading the Display:
Convert the hexadecimal display into binary display. If more than two causes, they will be added.
Example
When 42 is displayed:
Higher bit : 4 = 0100 
n b6
Lower bit : 2 = 0010 
n b1
In this case, the retry cause is combined of “CLV unlock” and “ader5”.
When A2 is displayed:
Higher bit : A = 1010 
n b7+b5
Lower bit : 2 = 0010 
n b2
The retry cause in this case is combined of “access fault”, “IVR rec error”, and “ader5”.