MDS-NT1 - Sony Audio Service Manual (repair manual). Page 34

Read Sony MDS-NT1 Service Manual online

34
MDS-NT1
5-15. ERROR RATE CHECK
5-15-1. CD Error Rate Check
Checking Procedure:
1. Load the check disc (MD) TDYS-1.
2. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “CPLAY2
MODE” (C36).
3. Click the
 [ENTER/YES]
 twice and display “CPLAY2MID”.
4. The display changes to “C = 
 AD = 
”.
5. Check that the C1 error rate is below 20.
6. Click the
[MENU/NO]
 to stop playback, then click the 
[EJECT]
and take out the check disc.
5-15-2. MO Error Rate Check
Checking Procedure:
1. Load the continuously-recorded disc.  (Refer to “5-6.  USING
THE CONTINUOUSLY RECORDED DISC”)
2. Click the 
[JOG UP]
 or 
[JOG DOWN]
 to display “CPLAY2
MODE” (C36).
3. Click the
 [ENTER/YES]
 to display “CPLAY2MID”.
4. The display changes to “C = 
 AD = 
”.
5. If the C1 error rate is below 20, check that ADER is 00.
6. Click the
[MENU/NO]
 to stop playback, then click the
[EJECT]
 and take out the test disc.
5-16. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Checking Procedure:
1. Load the continuously-recorded disc.  (Refer to “5-6.  USING
THE CONTINUOUSLY RECORDED DISC”)
2. Click the 
[JOG UP]
 or 
[JOG DOWN]
 to display “CPLAY2
MODE” (C36).
3. Click the 
[ENTER/YES]
 twice to display “CPLAY2MID”.
4. Click the 
[MENU/NO]
 when “C = 
 AD = 
” is displayed.
5. Click the 
[JOG  UP]
 or 
[JOG  DOWN]
 to display “FBIAS
CHECK” (C16).
6. Click the 
[ENTER/YES]
 to display “
/
 c = 
”.
The first four digits indicate the C1 error rate, the two digits
after “/ ” indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 20 and ADER is below 2.
7. Click the 
[ENTER/YES]
 and display “
/
 b = 
”.
Check that the C1 error is about 100 and ADER is below 2.
8. Click the 
[ENTER/YES]
 and display “
/
 a = 
”.
Check that the C1 error is about 100 and ADER is below 2
9. Click the 
[MENU/NO]
, then click the 
[EJECT]
 and take out
the disc.
Note:
If the C1 error and ADER are above other than the specified
value at points a (step 8. in the above) or b (step 7. in the above),
the focus bias adjustment may not have been carried out prop-
erly. Adjust perform the beginning again.
5-17. AUTO  GAIN  CONTROL  OUTPUT  LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the optical pick-up is
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.
5-17-1. CD Auto Gain Control Output Level Adjustment
Adjusting Procedure:
1. Load the check disc (MD) TDYS-1.
2. Click the 
[JOG UP]
 or 
[JOG DOWN]
 to display “AG Set (CD)”
(C11).
3. When the 
[ENTER/YES]
 is clicked, the adjustment will be
performed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (CD)” (C11).
4. Click the 
[EJECT]
 and take out the check disc.
5-17-2. MO Auto Gain Control Output Level Adjustment
Adjusting Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Click the 
[JOG UP]
 or 
[JOG DOWN]
 to display “AG Set
(MO)” (C10).
3. When the 
[ENTER/YES]
 is clicked, the adjustment will be
performed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (MO)” (C10).
4. Click the 
[EJECT]
 and take out the test disc.
Page of 70