– 26 –
5-13. ERROR RATE CHECK
5-13-1. CD Error Rate Check
Checking Procedure :
1. Load a check disc (MD) TDYS-1.
2. Rotate the  AMS  knob and display “CPLAY MODE”.
3. Press the  YES  button twice and display “CPLAY MID”.
4. The display changes to “C1 = 
 AD = 
”.
5. Check that the C1 error rate is below 20.
6. Press the  MENU/NO  button, stop playback, press the   
§  but-
ton, and remove the test disc.
5-13-2. MO Error Rate Check
Checking Procedure :
1. Load a test disc (MDW-74/AU-1).
2. Rotate the  AMS  knob and display “CPLAY MODE”.
3. Press the  YES  button and display “CPLAY MID”.
4. The display changes to “C1 = 
 AD = 
”.
5. If the C1 error rate is below 50, check that ADER is 00.
6. Press the  MENU/NO  button, stop playback, press the  
§  but-
ton, and remove the test disc.
5-14. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load a test disc (MDW-74/AU-1).
2. Rotate the  AMS  knob and display “CPLAY MODE”.
3. Press the  YES  button twice and display “CPLAY MID”.
4. Press the  MENU/NO  button when “C1 = 
 AD = 
” is
displayed.
5. Rotate the  AMS  knob and display “FBIAS CHECK”.
6. Press the  YES  button and display “ 
/
 c = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate the
focus bias value.
Check that the C1 error is below 50 and ADER is below 2.
7. Press the  YES  button and display “ 
/
 b = 
”.
Check that the C1 error is below 220 and ADER is below 2.
8. Press the  YES  button and display “ 
/
 a = 
”.
Check that the C1 error is below 220 and ADER is below 2
9. Press the  MENU/NO  button, next press the  
§  button, and
remove the continuously recorded disc.
Note 1 : If the C1 error and ADER are above other than the specified
value at points a (step 8. in the above) or b (step 7. in the
above), the focus bias adjustment may not have been car-
ried out properly. Adjust perform the beginning again.
5-15. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the pickup is replaced.
If the adjustment results becomes “Adjust NG!”, the pickup may be
faulty or the servo system circuits may be abnormal.
5-15-1. CD Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the check disc (MD) TDYS-1.
2. Rotate the  AMS  knob to display “AG Set (CD)”.
3. When the  YES  button is pressed, the adjustment will be
performed automatically.
“Complete!!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)”.
4. Press the  
§  button to remove the disc.
5-15-2. MO Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the reference disc (MDW-74/AU-1) for recording.
2. Rotate the  AMS  knob to display “AG Set (MO)”.
3. When the  YES  button is pressed, the adjustment will be
performed automatically.
“Complete!!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)”.
4. Press the  
§  button to remove the disc.
Page of 58
Display

Click on the first or last page to see other MDS-JE330 service manuals if exist.