MDS-DRE1 - Sony Audio Service Manual (repair manual). Page 13

Read Sony MDS-DRE1 Service Manual online

– 13 –
Function
PLAY/PAUSE
STOP
)
0
r REC
BANK
PLAY MODE
DISPLAY
Contents
Sets continuous playback when pressed in the STOP state. When pressed during continuous playback, the tracking servo
turns ON/OFF.
Stops continuous playback and continuous recording.
The sled moves to the outer circumference only when this is pressed.
The sled moves to the inner circumference only when this is pressed.
Turns recording ON/OFF when pressed during continuous playback.
Switches between the pit and groove modes when pressed.
Switches the spindle servo mode (CLVS and A).
Switches the display when pressed.Returns to previous step. Stops operations.
Note:
The erasing-protection tab is not detected during the test mode. Recording will start regardless of the position of the erasing-protection tab when the
[   REC]
  button is pressed.
4-4-2. Operating the Continuous Recording Mode
1. Entering the continuous recording mode
1 Set the MO disc in the unit.
2 Rotate the 
[AMS]
 knob and display “CREC MODE”.
3 Press the 
[ENTER/YES]
 button to change the display to “CREC IN”.
4 When access completes, the display changes to “CREC (
” and  
REC
  lights up.
Note : 
The “ ” displayed are arbitrary numbers.
2. Changing the parts to be recorded
1 When the 
[ENTER/YES]
 button is pressed during continuous recording, the display changes to “CREC MID”, “CREC OUT” and
REC
  goes off.
When pressed another time, the parts to be recorded can be changed.
2 When access completes, the display changes to “CREC (
” and  
REC
  lights up.
Note : 
The “ ” displayed are arbitrary numbers.
3. Ending the continuous recording mode
1 Press the 
[EDIT/NO]
 button. The display changes to “CREC MODE” and  
REC
  goes off.
2 Press the 
[   EJECT]
 button and remove the disc.
Note 1: 
The recording start addresses for IN, MID, and OUT are as follows.
IN
40h cluster
MID
300h cluster
OUT
700h cluster
Note 2:
The 
[EDIT/NO]
 button can be used to stop recording anytime.
Note 3:
During the test mode, the erasing-protection tab will not be detected. Therefore be careful not to set the continuous recording mode when a
disc not to be erased is set in the unit.
Note 4:
Do not perform continuous recording for long periods of time above 5 minutes.
Note 5:
During continuous recording, be careful not to apply vibration.
4-4-3. Non-Volatile Memory Mode (EEP MODE)
This mode reads and writes the contents of the non-volatile memory.
It is not used in servicing. If set accidentally, press the 
[EDIT/NO]
 button immediately to exit it.
4-5. Functions of Other buttons
§
r
Page of 79