MDS-B6P - Sony Audio Service Manual (repair manual). Page 10

Read Sony MDS-B6P Service Manual online

— 34 —
4-1. Precautions for Checking Laser Diode
Emission
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
4-2. Precautions for Use of Optical Pick-up
(KMS-210A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ing the connector, be careful not to remove the solder. Also take ad-
equate measures to prevent damage by static electricity. Handle the
flexible board with care as it breaks easily.
SECTION  4
ELECTRICAL ADJUSTMENTS
4-3. Precautions for Adjustments
1) When replacing the following parts, perform the adjustments and
checks with 
® in the order shown in the following table.
Optical
Pick-up
BD Board
G
®
®
®
®
®
®
®
®
®
®
G
G
G
®
®
®
®
®
1. Temperature
compensation
offset adjustment
2. Laser power
adjustment
3. Traverse
adjustment
4. Focus bias
adjustment
5. Error rate check
IC171
IC101, IC121, IC191
D101
G
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3) Perform the adjustments in the order shown.
4) Use the following tools and measuring devices.
• MD test disc (CD) MDW-74/AU-1 (Parts No. 8-892-341-41)
• MD test disc TDYS-1
(Parts No. 4-963-646-01)
• Laser power meter LPM-8001
(Parts No. J-2501-046-A)
• Oscilloscope
• Digital voltmeter
• Thermometer
5) When observing several signals on the oscilloscope, etc.,
make sure that VC and GND do not connect inside the oscillo-
scope.
(VC and GND will become short-circuited.)
Optical pick-up flexible board
laser tap
Page of 58