ICF-S10MK2 (serv.man2) - Sony Audio Service Manual (repair manual). Page 6

Read Sony ICF-S10MK2 (serv.man2) Service Manual online

6
ICF-S10MK2
SECTION  4
ELECTRICAL  ADJUSTMENTS
0 dB=1 
µ
V
[AM]
Setting:
BAND switch : AM
[FM]
Setting:
BAND switch : FM
• Repeat the procedures in each adjustment several times for a
maximum reading on level meter, and the frequency coverage
and tracking adjustment should be finally done by the trimmer
capacitors.
Adjustment Location:
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
16 
jack (J1)
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: as low as possible
+
level meter
v
 jack (J1)
set
16 
0.01 
µ
F
TP (FM ANT)
– MAIN BOARD (Component Side) –
CT1
}
AM Tracking
L1
Adjustment
T1
AM IF
Adjustment
L3
}
FM Tracking
CT2
Adjustment
CT4
}
AM Frequency Coverage
L4
Adjustment
L2
}
FM Frequency Coverage
CT3
Adjustment
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
455 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L4
520 kHz
CT4
1,650 kHz
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
620 kHz
CT1
1,400 kHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L2
86.5 MHz
CT3
109.5 MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3
87.5 MHz
CT2
108 MHz
Page of 19