ICF-M770L, ICF-M770S, ICF-M770SL - Sony Audio Service Manual (repair manual). Page 6

Read Sony ICF-M770L / ICF-M770S / ICF-M770SL Service Manual online

6
ICF-M770L/M770S/M770SL
no mark : common
(
) : ICF-M770L
[
] : ICF-M770S
〈〈
〉〉 : ICF-M770SL
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
MW VT VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
(L8) [L10]
531 kHz
2.5 
± 0.1 V [2.8 ± 0.1 V]
Confirmation
1,602 kHz
9.6 
± 1.0 V
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
(L5-1) [L5]
603 kHz
(CT1) [CT2]
1,404 kHz
LW VT VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
(CT3) 
〈〈L10〉〉
153 kHz
2.2 
± 0.1 V 〈〈2.8 ± 0.1 V〉〉
Confirmation
279 kHz
8.6 
± 1.0 V
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
(L5-2) 
〈〈L5〉〉
162 kHz
CT2
243 kHz
FM VT VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L14
87.5 MHz
2.9 
± 1.0 V
Confirmation
108 MHz
9.1 
± 1.0 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L12, 13
87.5 MHz
CT4
108 MHz
SW VT VOLTAGE ADJUSTMENT
*
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L8
5,800 kHz
2.7 
± 0.1 V
Confirmation
15,900 kHz
9.1 
± 1.0 V
SW TRACKING ADJUSTMENT
*
Adjust for a maximum reading on level meter
L3
5,800 kHz
CT1
15,900 kHz
*: ICF-M770S/M770SL
Adjustment Location: MAIN board (See page 7)
0 dB=1 
µ
V
[MW/LW]
Setting:
BAND switch: MW or LW
[FM]
Setting:
BAND switch: FM
[SW] (ICF-M770S/M770SL)
Setting:
BAND switch: SW
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM/SW antenna in FM/SW adjustment.
digital voltmeter
100 k
MAIN board
TP (VT)
+
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
+
level meter
set
32 
11 pF
MAIN board
TP (ANT)
JACK board
v
 jack (J201)
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: as low as possible
+
level meter
set
32 
0.01 
µ
F
MAIN board
TP (ANT)
JACK board
v
 jack (J201)
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
32 
JACK board
v
 jack (J201)
SECTION  4
ELECTRICAL  ADJUSTMENTS
Page of 22
Display