ICF-M60LRDS, ICF-M60SRDS - Sony Audio Service Manual (repair manual). Page 7

Read Sony ICF-M60LRDS / ICF-M60SRDS Service Manual online

7
ICF-M60LRDS/M60SRDS
no mark: M60LRDS
(
): M60SRDS
MW VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L5
531 kHz
2.55 
± 0.05 V (2.7 ± 0.05 V)
Confirmation
1602 kHz
8.7 
± 0.5 V (9.6 ± 0.5 V)
no mark: M60LRDS
(
): M60SRDS
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L6-1 (L4)
603 kHz
CT2
1404 kHz
LW VCO VOLTAGE ADJUSTMENT (M60LRDS)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
CT5
153 kHz
2.35 
± 0.05 V
Confirmation
279 kHz
9.6 
± 0.5 V
LW TRACKING ADJUSTMENT (M60LRDS)
Adjust for a maximum reading on level meter
L6-2
162 kHz
CT3
243 kHz
SW VCO VOLTAGE ADJUSTMENT (M60SRDS)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L8
5800 kHz
2.6 
± 0.05 V
Confirmation
15900 kHz
9.6 
± 0.5 V
SW TRACKING ADJUSTMENT (M60SRDS)
Adjust for a maximum reading on level meter
L7
5800 kHz
CT6
15900 kHz
FM VCO VOLTAGE CONFIRMATION
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
Confirmation
87.5 MHz
1.3 
± 0.3 V
Confirmation
108 MHz
8.5 
± 1.5 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1, 2
87.5 MHz
CT1
108 MHz
Adjustment Location: MAIN board (See page 9)
0 dB=0.280 mV
[AM (MW/LW)]
Setting:
BAND button : MW or LW
[AM (SW)] (M60SRDS)
Setting:
BAND button: SW
[FM]
Setting:
BAND button: FM
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM antenna in FM adjustment.
SECTION  4
ELECTRICAL  ADJUSTMENTS
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
8.0 
JACK board
TP (SP OUT –)
JACK board
TP (SP OUT +)
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
+
level meter
JACK board
TP (SP OUT –)
JACK board
TP (SP OUT +)
set
8.0 
11 pF
MAIN board
TP (GND)
MAIN board
TP (ANT IN)
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: 
as low as possible
+
level meter
JACK board
TP (SP OUT –)
JACK board
TP (SP OUT +)
set
8.0 
0.01 
µ
F
MAIN board
TP (GND)
MAIN board
TP (ANT IN)
digital voltmeter
TP (VT)
TP (GND)
100 k
MAIN board
Page of 28
Display