ICF-J1 - Sony Audio Service Manual (repair manual). Page 9

Read Sony ICF-J1 Service Manual online

– 9 –
AM  IF  ADJUSTMENT
Adjust for a maximum reading on level meter
T1
455 kHz
MW  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter
L5
516.5 kHz
CT1-4
1,631.5 kHz
MW  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L1
600 kHz
CT1-1
1,400 kHz
SW  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter
L6
4.7 MHz
CT6
18.5 MHz
SW  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L2
4.75 MHz
CT5
18 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L4
87.35 MHz
CT1-3
108.25 MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3
87.5 MHz
CT1-2
108 MHz
Adjustment Location: MAIN board (See page 10)
SECTION  4
ELECTRICAL  ADJUSTMENTS
0 dB=1 
µ
V
[MW]
Setting:
Band switch : MW
[SW]
Setting:
Band switch : SW
[FM]
Setting:
Band switch : FM
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
• Remove FM/SW antenna in SW and FM adjustments.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
TP9 (SP –)
TP8 (SP +)
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
+
level meter
TP9 (SP –)
TP8 (SP +)
TP1
 (ANT IN)
set
12 pF
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: as low as possible
+
level meter
TP9 (SP –)
TP8 (SP +)
TP1
 (ANT IN)
set
0.01 
µ
F
Page of 17