ICF-CD873L - Sony Audio Service Manual (repair manual). Page 11

Read Sony ICF-CD873L Service Manual online

– 11 –
MAIN  CLOCK  SECTION
Main Clock Adjustment
Connection:
Adjustment jig:
Procedure:
1. Connect the frequency counter as the above figures.
2. Adjust CT401 for 4.2495 MHz reading on the frequency
counter.
Specified Value: 4.2490 to 4.2500 MHz
+
adjustment
jig
10 : 1 probe
TP (+5 V)
TP401 (X2)
TP GND (SHIELD) 
+5
IN
GND
frequency counter
MAIN board
OUT
GND
 1 M
 100 k
 100 k
 +5 V
 0.5 pF
 47 uF
 IN
 GND
 1000 pF
 1 M
OUT
GND
INVERTER
(TC7W04F)
+
Page of 36
Display