ICF-CD873 - Sony Audio Service Manual (repair manual). Page 10

Read Sony ICF-CD873 Service Manual online

– 10 –
CD SECTION
Note:
Tracking Balance Adjustment and Tracking Gain Adjustment are
done automatically in this set.
TEST MODE
1. Press the CD LID OPEN/CLOSE DET switch (S424) on the
PUSH SWITCH board.
2. Under standby condition (when the clock appear in the dis-
play), short the BP (CD TEST AUTO).
Note:
 If the power is supplied to the microprocessor once, it is backed up
for 3 minutes, therefore the TEST mode will not be activated within
3 minutes even if the power is turned on again. In this case, short
instantaneously the BP (CD TEST MANUAL).
3. Press the  ^ key, and the focus search is repeated.
At this time, check that the optical pick-up objective lens moves
smoothly without a sticking or noise.
4. Load the test disc (YEDS-18: Part No. 3-702-101-01), and per-
form automatic adjustment after the focus search succeded.
5. After automatic adjustment is finished, move the sled motor
to the center. At this time, keep pressing the + and =
keys to confirm that optical pick-up moves smoothly via most
inside track 
 most outside track 
 most inside track with-
out a sticking or noise.
6. Confirm the traverse waveform.
7. Press the [WAKE UP TRACK] key.
8. The tracking servo and the sled servo are turned on, the mute
is cancelled.
9. Playback the 2nd track.
10. Adjust the RF and jitter waveforms.
Connecting points: MAIN Board (See page 13)
Focus Bias Adjustment
This adjustment is to be done when the optical block is replaced.
Connection:
Adjustment Procedure:
1. Connect the oscilloscope to TP504 (VREF) and TP503 (RF)
on the MAIN board.
2. Insert the test disc (YEDS-18: Part No.3-702-101-01) and press
^ key to play.
3. Move the optical pick-up to the music area on the disc to en-
able easy visibility of the eye pattern by + or = key
pressing.
4. Adjust RV501 so that the oscilloscope waveform is as shown
in the figure below (eye pattern).
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Adjustment Location: MAIN Board (See page 13)
MAIN board
TP503 (RF)
TP504 (VREF)
+
oscilloscope
(AC range)
VOLT/DIV: 0.2 V
TIME/DIV: 500 ns
1.3 
±
 0.5 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.