SECTION  4
ELECTRICAL  ADJUSTMENTS
FM VCO Adjustment
Procedure:
FM RF signal
generator
Carrier frequency: 98 MHz
Modulation: no modulation
Output level: 0.1 V (100 dB)
0.01 
µF
FM lead wire antenna terminal
Connection:
Adjustment Location:
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L4
530 kHz
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3-1
600 kHz
CT2
1,400 kHz
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L2
87.5 MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108.0 MHz
PRECAUTION
• Adjustment should be performed in the order given.
[FM]
Setting:
Function switch : RADIO
BAND switch
: FM
[AM]
Setting:
Function switch : RADIO
BAND switch
: MW/LW signal
AM RF signal 
generator
30% amplitude modulation by 
400 Hz signal.
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
75 kHz frequency deviation 
by 1 kHz signal.
Output level: as low as possible
0.01 
µF
FM lead wire antenna terminal
level meter
set
J301 (phones)
32 
+
TUNER  SECTION
0 dB=1 µV
Frequency counter
75,500 – 76,500 Hz
IC1 Pin 4
+
frequency counter
33 k 
MAIN Board
IC1 Pin 7
RV1
FM VCO Adjustment 
T1  
AM IF Adjustment
CT2
MW Traking Adjustment
L2  
FM Frequency 
Coverage Adjustment
L4 
MW Frequency 
Coverage Adjustment
L1  
FM Tracking Adjustment
CT1  
FM Traking 
Adjustment
L3-2  
LW Traking Adjustment
L3-1
MW Traking Adjustment
CT3
LW Traking Adjustment
CT4 
LW Frequency 
Coverage Adjustment
[MAIN BOARD] (Component Side)
LW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
CT4
153 kHz
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3-2
162 kHz
CT3
243 kHz
1. Connect the frequency counter to 4 and 7 pins of IC1 as shown
the figure right.
2. Tune the set to 98 MHz.
3. Adjust RV1 for 76 kHz reading on frequency counter.
Specification Value: