Perform all CD section check in the test mode.
FOCUS  BIAS  CHECK
Procedure:
1. Connect the oscilloscope to TP (RF) and TP (VREF) on the
CD board.
2. Insert the test disc (PATD-012). (Part No. 4-225-203-01) (CD)
3. While playing the CD, set the CD test mode (Refer to CD
TEST MODE (See page 11)) (Automatic adjustment value is
held at this time).
4. Set the FOCUS 2 MODE.
5. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the
center of the waveform can be clearly distinguished.
6. Release the CD test mode.
7. Change the test disc (TCD-W082L). (Part No. J-2502-063-2)
(CD-RW)
8. Perform confirmation in the same manner as step 3 to 6.
• RF signal reference waveform (eye pattern)
Connecting Location:
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
CD:
1.0 to 1.6 Vp-p
CD-RW:
1.2 
±
 1.8 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
– CD BOARD (Conductor Side) –
IC701
TP (RF)
TP (VREF)