5-7-7. B-SUB BRT (B-CH SUB BRIGHT) ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope of 1 step voltage to the TP1960 on
1. Connect an oscilloscope of 1 step voltage to the TP1960 on
the TV board.
2. Adjust the
.
/
>
keys so that the G level of the wave-
form on the oscilloscope is 1.0
± 0.1 Vp-p.
5-7-8. R-SUB CONT (R-CH SUB CONTRAST)
ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope of 10 step voltage to the TP1958 on
1. Connect an oscilloscope of 10 step voltage to the TP1958 on
the TV board.
2. Adjust the
.
/
>
keys so that the D level of the wave-
form on the oscilloscope is 3.25
± 0.1 Vp-p.
5-7-9. B-SUB CONT (B-CH SUB CONTRAST)
ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope of 10 step voltage to the TP1960 on
1. Connect an oscilloscope of 10 step voltage to the TP1960 on
the TV board.
2. Adjust the
.
/
>
keys so that the D level of the wave-
form on the oscilloscope is 3.25
± 0.1 Vp-p.
5-7-3. Y GAIN (LUMINANCE SIGNAL CONTRAST
LEVEL) ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope to the TP1959 on the TV board.
2. Adjust the
1. Connect an oscilloscope to the TP1959 on the TV board.
2. Adjust the
.
/
>
keys so that the D level of the wave-
form on the oscilloscope is 3.25
± 0.1 Vp-p.
5-7-4. BLACK LIMIT (BLACK LIMITER LEVEL)
ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope to the TP1959 on the TV board.
2. Adjust the
1. Connect an oscilloscope to the TP1959 on the TV board.
2. Adjust the
.
/
>
keys so that the E level of the wave-
form on the oscilloscope is 1.0
± 0.1 Vp-p.
5-7-5. WHITE LIMIT (WHITE LIMITER LEVEL)
ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope to the TP1959 on the TV board.
2. Adjust the
1. Connect an oscilloscope to the TP1959 on the TV board.
2. Adjust the
.
/
>
keys so that the F level of the wave-
form on the oscilloscope is 3.9
± 0.05 Vp-p.
5-7-6. R-SUB BRT (R-CH SUB BRIGHT) ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope of 1 step voltage to the TP1958 on
1. Connect an oscilloscope of 1 step voltage to the TP1958 on
the TV board.
2. Adjust the
.
/
>
keys so that the G level of the wave-
form on the oscilloscope is 1.0
± 0.1 Vp-p.
G
0V
G
0V
D
0V
D
0V
F
0V
D
0V
D
0V