ICF-CD553RM - Sony Audio Service Manual (repair manual). Page 11

Read Sony ICF-CD553RM Service Manual online

11
ICF-CD553RM
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
AM VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L6
530 kHz
1.0 
± 0.05 V
Confirmation
1,710 kHz
5.3 
± 0.7 V
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L5
580 kHz
CT5
1,490 kHz
FM/TV/WEATHER IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2
10.7 MHz
FM/TV (2 – 6 CH) VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
TV 2 ch
0.55 
± 0.15 V
CT3
108 MHz
4.5 
± 0.15 V
FM/TV (2 – 6 CH)  TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L2
TV 2 ch
Confirmation
108 MHz
TV (7 – 13 CH)/WEATHER (1 – 7 CH) VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L3
WEATHER 2 ch
1.2 
± 0.15 V
CT4
TV 13 ch
4.1 
± 0.15 V
TV (7 – 13 CH)/WEATHER (1 – 7 CH)  TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
WEATHER 2 ch
CT2
TV 13 ch
Adjustment and Connecting Location: TUNER board
(See page 12)
TUNER  SECTION
0 dB=1 
µ
V
[AM]
Setting:
Function: RADIO
Band: AM
[FM/TV/WEATHER]
Setting:
Function: RADIO
Band: FM/TV/WEATHER
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
AMP board
CN301 pin 
2
AMP board
CN301 pin 
1
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz
signal
Output level: 
as low as possible
+
level meter
AMP board
CN301 pin 
2
AMP board
CN301 pin 
1
set
0.01 
µ
F
TUNER board
TP (GND)
TUNER board
TP (ANT)
digital voltmeter
TP (VT)
TP (GND)
100 k
TUNER board
SECTION  5
ELECTRICAL  ADJUSTMENTS
Page of 49
Display