ICF-CD523 - Sony Audio Service Manual (repair manual). Page 13

Read Sony ICF-CD523 Service Manual online

13
ICF-CD523
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
(     ): AEP model
AM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 kHz
(531 kHz)
2.65 
±
 0.1 V
Confirmation
1,710 kHz
8.8 
±
 0.5 V
(1,602 kHz)
(8.5 
±
 0.5 V)
(     ): AEP model
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L3
580 kHz (621 kHz)
CT2
1,490 kHz (1,404 kHz)
FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
87.5 MHz
2.6 
±
 0.1 V
Confirmation
108 MHz
8.0 
±
 0.5 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment Location: MAIN board (See page 15)
FM  VCO ADJUSTMENT
Setting:
Procedure:
1. Connect the frequency counter to TP(STVCO), TP(TU - +B)
on the MAIN board, as shown the figure below.
2. Tune the set to 98 MHz.
3. Adjust RV1 on the MAIN board for 76 kHz reading on the
frequency counter.
Specified Value: 75.95 to 76.05 kHz
Adjustment Location: MAIN board (See page 15)
SECTION  5
ELECTRICAL  ADJUSTMENTS
TUNER  SECTION
0 dB=1 
µ
V
[AM]
Setting:
Function : RADIO
Band
: AM
[FM]
Setting:
Function : RADIO
Band
: FM
• Attention
BP1 Desoldering
(Must be short after measurement)
• Repeat the procedures in each adjustment several times, and
tracking adjustments should be finally done by the trimmer
capacitors.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
MAIN board
speaker terminal (CN301)
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: as low as possible
+
level meter
set
0.01 
µ
F
MAIN board
TP (FMIN)
MAIN board
speaker terminal (CN301)
TP (FEG)
digital voltmeter
100 k
MAIN board
TP (VT)
FM RF SSG
Carrier frequency: 98 MHz
Modulation: 400 Hz, 30% FM modulation
Output level: 0.1 V (100 dB)
MAIN board
TP (FMIN)
0.01 
µ
F
set
TP (FEG)
µ
F
TP (STVCO)
+
frequency counter
33 k
TP (TU - +B)
+
MAIN board
Ver. 1.1