– 4 –
1-673-930-
11
(11)
C586
C585
C587
C493
C495
R478
R844
99
R476
C419
R483
R477
C551
C545
C565
C569
C807
C806
C805
R591
R567
C505
R565
R850
C619
C609
C542
R535
C536
C533
C555
R851
C554
R524
C516
R525
R501
R575
R576
R558
R557
R566
R854
R568
C504
C559
C506
R584
R631
C540
R552
R553
R549
C494
FB401
L508
L515
C510
L501
C801
C553
C552
C803
R632
C502
C519
R539
D512
D501
Q601
IC404
C534
+
C543
+
C610
+
C608
+
C541
+
C535
+
C520
+
C564
+
C568
+
C595
+
C515
+
C561
+
14
13
8
1
9
16
AK
A
K
D504
A
A
K
Q514
Q507
Q505
B C E
B C E
BC
E
BC
E
Q503
2E2B 1C
2C1B 1E
Q502
2E2B1C
2C1B 1E
2B 2E
TP
(IOP 0)
TP
(IOP 1)
1C
1B 2C
1E
2C
1B
1E
2E
2B
1C
Q501
Q513
L511
TP
(RF)
TP
(TE)
TP
(GND)
TP
(VC)
+
digital voltmeter
(DC3 V range)
• Method-2 (In the service mode or normal operation):
Check the value of current flowing in the laser diode.
1. Remove the upper panel.
2. Connect a digital voltmeter as show in Fig. 2.
3. Press the 
[CD     ]
 key.
4. Calculate current value by the reading of the digital voltmeter.
Reading of the digital voltmeter (V) 
÷
 2.2 (
) = current value
(A)
(Example) Reading of the digital voltmeter of 0.082 V:
0.082 V
÷
2.2 
= 0.037 (A) = 37 mA
Current value of the specified: 16 to 18 mA
5. Check that the current value is within the following range.
• Current value of the specified 
 mA (25 ˚C)
Variation by temperature: 0.4 mA/˚C
Current increases with temperature increased.
Current decreases with temperature decreased.
If the current is more than the range above, there is a trouble
in the automatic power control circuit or the laser diode is in
deterioration.
If less than the range, a trouble exists in the automatic power
control circuit or the optical pick-up.
– MAIN  Board (Conductor Side) –
Fig. 2  Digital voltmeter connecting location
u
+5
–11
Page of 47
Display