ICF-C900HS - Sony Audio Service Manual (repair manual). Page 6

Read Sony ICF-C900HS Service Manual online

– 6 –
SECTION  3
ELECTRICAL  ADJUSTMENTS
TUNER  SECTION
[FM]
Setting:
BAND switch: FM
[AM]
Setting:
BAND switch: AM
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
FM RF signal 
generator
400 Hz, 30% FM modulation
frequency deviation 
±
 22.5 kHz
Output level: as low as possible
MAIN board
TP (FMIN)           
0.01 
µ
F
AM RF signal 
generator
400 Hz, 30%
AM modulation
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
level meter
+
MAIN board
TP (SP-OUT)
FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
86.5 MHz
CT1-3
109.5 MHz
FM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.5 MHz
CT1-2
109.5 MHz
AM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520 kHz
CT1-4
1,650 kHz
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
600 kHz
CT1-1
1,400 kHz
AM  IF  ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455 kHz
DATA  TX  SECTION
DATA  TRANSMISSION  LEVEL  ADJUST
Setting:
RANDOM switch: OFF
Schematic Diagrams of the filter unit:
Adjusting Procedure:
1. Insert the AC plug of set into the AC Outlet of filter unit while
pressing 
[D.S.T SUMMER T]
[CLOCK]
,
[SNOOZE/DATE/SLEEP OFF]
 buttons simultaneously.
2. All LCD segment are turned on, and the test mode will start.
3. Press all button one by one as below,
[D.S.T SUMMER T]
[CLOCK]
[TIME SET–]
[TIME SET+]
[ALARM A]
[ALARM B]
[LIGHT 1]
[LIGHT 2]
[SNOOZE/DATE/SLEEP OFF]
[RADIO OFF, ALARM SET]
[RADIO ON,  SLEEP]
4. Set 
[RANDOM]
 Switch to OFF 
n ON n OFF position, and
the display “OFF TIME0*” are appear.
5. Press 
[1]
 button to blink the display “OFF TIME*” and the
carrier signal output continuity,
(*: ID code No.)
6. Adjust T2 to 0.45 V observing AC voltmeter.
Adjustment Value:
Adjustment part
STANDARD VALUE
T2
 0.35 V to 0.55 V
7. To exit from test mode, disconnect the power cord of set.
filter unit
AC voltmeter
AC outlet
measure
terminal
AC120 V, 60 Hz
set
+
AC outlet
measure
terminal
11 
62 
0.1
µ
F
0.1
µ
F
1 mH
1 mH
Page of 17
Display

Click on the first or last page to see other ICF-C900HS service manuals if exist.