5-2.   RADIO SECTION
  AM
  FM
Put the lead-wire
antanna close to
the set.
30% amplitude
modulation by
400 Hz signal
AM rf signal
generator
set
speaker terminal
FM rf signal
generator
22.5 kHz frequency deviation
by 400 Hz signal
output level : as low as possible
to FM antenna
    terminal
0.01 µF
set
speaker terminal
level meter
(range : 0.5 – 5 V ac)
• Repeat the procedures is each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
Adjustment Location : main board (component side)
CT2   L2
CT4   L4
CT1   L1
CT3
FM
TRACKING
ADJ
AM
TRACKING
ADJ
T1
AM IF
ADJ
VR2
TAPE SPEED
ADJ
AM  IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455 kHz
AM FREQUENCY COVERAGE
ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
CT2
520 kHz (516.5 kHz)
1,650 kHz (1,631.5 kHz)
AM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
600 kHz
1,400 kHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
CT4
86.5 MHz (87.35 MHz)
109.5 MHz (108.25 MHz)
FM  TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
(confirmation)
CT3
86.5 MHz (87.35 MHz)
109.5 MHz (108.25 MHz)
(           ) : Italian model
level meter
(range : 0.5 – 5 V ac)
AM
FREQUENCY
COVERAGE ADJ
FM
FREQUENCY
COVERAGE ADJ
Page of 17