ICF-C411 - Sony Audio Service Manual (repair manual). Page 7

Read Sony ICF-C411 Service Manual online

7
ICF-C411
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
86.5 MHz
109.5 MHz
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
CT2
86.5 MHz
109.5 MHz
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
CT4
515 kHz
1,750 kHz
AM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
600 kHz
1,400 kHz
  FM SECTION     0 dB = 1 µV
Setting:
BAND switch: FM
VOLUME control: MIN
  AM SECTION
Setting:
BAND switch: AM
VOLUME control: MIN
SECTION 4
ELECTRICAL ADJUSTMENTS
FM lead wire
antenna terminal
0.01
µ
F
FM RF signal
generator
400Hz, 30% FM modulation
frequency deviation 
±
22.5kHz
Output level: as low as possible
set
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
400Hz, 30%
 AM modulation
Output level: as low as possible
• Connecting Level Meter (FM and AM)
Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally done
by the trimmer capacitors.
speaker terminal
set
16 
level meter
(range: 0.5–5 V ac)
Adjustment Location: See page 8.
Page of 20