ICF-C160 - Sony Audio Service Manual (repair manual). Page 2

Read Sony ICF-C160 Service Manual online

– 2 –
Mark 1 Mark 2
Center
frequency
red
10.70MHz
blue
10.67MHz
orange
10.73MHz
black
10.64MHz
white
10.76MHz
white
white
10.75 MHz
yellow
10.79 MHz
HOW  TO  CHANGE  THE  FM  CERAMIC  FILTERS
This model is used two ceramic filters of CF1 and CF3.
You must use same type of color marked ceramic filters in order
to meet same specifications.
Therefore, the ceramic filter must change two pieces together since
it's supply two pieces in one package as a spare parts.
ATTENTION  AU  COMPOSANT  AYANT  RAPPORT
À  LA  SÉCURITÉ!
LES  COMPOSANTS  IDENTIFIÉS  PAR  UNE  MARQUE  
!
SUR  LES  DIAGRAMMES  SCHÉMATIQUES  ET  LA  LISTE
DES  PIÈCES  SONT  CRITIQUES  POUR  LA  SÉCURITÉ
DE  FONCTIONNEMENT.  NE  REMPLACER  CES  COM-
POSANTS  QUE  PAR  DES  PIÈCES  SONY  DONT  LES
NUMÉROS  SONT  DONNÉS  DANS  CE  MANUEL  OU
DANS  LES  SUPPLÉMENTS  PUBLIÉS  PAR  SONY.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the fol-
lowing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs,
screws, and all other exposed metal parts for AC leakage. Check
leakage as described below.
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indica-
tion is 0.75 V, so analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex-
amples of a passive VOM that is suitable. Nearly all battery
operated digital multimeters that have a 2 V AC range are
suitable.  (See Fig. A)
CF1
mark 2
CF3
mark 2
mark 1
Fig. A.
Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  
!
  OR  DOTTED
LINE  WITH  MARK  
!
  ON  THE  SCHEMATIC  DIAGRAMS
AND  IN  THE  PARTS  LIST  ARE  CRITICAL  TO  SAFE
OPERATION.  REPLACE  THESE  COMPONENTS  WITH
SONY  PARTS  WHOSE  PART  NUMBERS  APPEAR  AS
SHOWN  IN  THIS  MANUAL  OR  IN  SUPPLEMENTS  PUB-
LISHED  BY  SONY.
Note on chip component replacement
Never reuse a disconnected chip component.
Notice that the minus side of a tantalum capacitor may be dam-
aged by heat.
CORD DRESSING
(POWER, ANTENNA)
1) Connect the power cord and antenna cord as shown in the
figure.
2) Mount the cord stopper with screws (P3 
×
 10).
Note: Tighten completely the screws (P3 
×
 10).
SECTION  1
SERVICING  NOTE
chassis
antenna cord
power cord
screw
(P3 
×
 10)
cord stopper
Page of 11
Display