ICF-903L - Sony Audio Service Manual (repair manual). Page 6

Read Sony ICF-903L Service Manual online

– 6 –
16 
set
v
 jack (EPJ1)
level meter
16 
set
v
 jack (EPJ1)
level meter
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
400Hz, 30% 
AM modulation
Output level: as low as possible
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
400Hz, 30% 
AM modulation
Output level: as low as possible
SECTION 3
ELECTRICAL ADJUSTMENTS
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
455 kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L5
520 kHz
CT4
1,650 kHz
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L2-1
600 kHz
CT1
1,400 kHz
3-1. MW SECTION
BAND switch : MW
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
LW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
CT6
145 kHz
<confirmation>
265 kHz
LW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L2-2
160 kHz
CT2
240 kHz
3-2. LW SECTION
BAND switch : LW