4-16. KEY
COUNT
The count value of the keys and switches operation can be dis-
played. However, distinction of kind of the keys and switches
which operated is not performed.
played. However, distinction of kind of the keys and switches
which operated is not performed.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “KEY COUNT”,
and press the [
N
] key.
3. The count value of the keys and switches operation is dis-
played.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
00888
<KEY COUNT>
LCD Display
Count value increase conditions:
One of buttons is pushed.
One of switches is slid.
Headphone or microphone is inserted.
Releasing method:
Remove battery.
Remove battery.
4-17. SLEEP
It can change into the sleep state for standby current value mea-
surement.
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “SLEEP”, and press
the [
N
] key.
3. The sleep state selection screen is displayed.
This unit shifts to the sleep state by pressing the [
N
] key
again.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
SLEEP:NORMAL
Excuting...
Excuting...
<SLEEP>
LCD Display
Releasing method:
Remove battery.
Remove battery.
4-18. BATT
LIFE
Not used for the servicing.
4-19. WRITER
VER
Not used for the servicing.
4-20. CHG
LOG
The charge log saved at SRAM can be copied to eMMC.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “CHG LOG”, and
press the [
N
] key.
3. The charge log saved at SRAM is copied to eMMC.
Success
<CHG LOG>
LCD Display
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-21. LREC
LOG
Not used for the servicing.
4-22. LREC LOG Clear
Not used for the servicing.
Not used for the servicing.
4-23. MENU
INIT
This unit can return to the factory shipment settings.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “MENU INIT”, and
press the [
N
] key.
3. Initialization is performed.
Formatting...
<MENU INIT>
LCD Display
4. “Success” is displayed, and this unit reboots.
Success
LCD Display