ICD-UX522, ICD-UX522F, ICD-UX523, ICD-UX523F - Sony Audio Service Manual (repair manual). Page 15

Read Sony ICD-UX522 / ICD-UX522F / ICD-UX523 / ICD-UX523F Service Manual online

ICD-UX522/UX522F/UX523/UX523F
15
4-12. VBUS
VBUS detection signal can be checked.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “VBUS”, and press 
the [
N
/ENTER] key.
3.  The state of VBUS_XDET is displayed.
<VBUS>
OFF
LCD Display
*Displayed characters/values are example.
 OFF 
VBUS_XDET=1 
(H)
 ON 
VBUS_XDET=0 
(L)
 
Key input settings under this mode of operation:
 
[
N
/ENTER]  : It shifts to the suspension state.
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-13.  FM TEST (ICD-UX522F/UX523F only)
FM tuner can be checked.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “FM TEST”, and 
press the [
N
/ENTER] key.
3.  The state of FM tuner is displayed.
<FM TEST>
FM: OK DX
80.00  Lv: 5A
CH: 80.00
LCD Display
*Displayed characters/values are example.
 
OK  : ID acquisition value OK
 
NG  : ID acquisition value NG
 
In OK, it becomes FM receiving mode.
 
Key input settings under this mode of operation:
 
[.] 
: Receiving step value decrease
 
[>] 
: Receiving step value increase
 
[
N
/ENTER] : Receiving sensitivity change (DX ↔ LOCAL)
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-14. KEY 
COUNT
The count value of the keys and switches operation can be dis-
played. Distinction of the keys and switches which operated is not 
performed.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “KEY COUNT”, 
and press the [
N
/ENTER] key.
3.  The count value of the keys and switches operation is dis-
played.
<KEY COUNT>
00888
LCD Display
*Displayed characters/values are example.
 
Count value increase conditions:
 
One of buttons is pushed.
 
One of switches is slid.
 
micro SD card is inserted.
 
Headphone or microphone is inserted.
Releasing method:
Remove battery.
4-15. SLEEP
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “SLEEP”, and press 
the [
N
/ENTER] key.
3.  The sleep state selection screen is displayed.
 
This unit shifts to the sleep state by pressing the [
N
/ENTER] 
key again.
<SLEEP>
SLEEP:NORMAL
Excuting...
LCD Display
*Displayed characters/values are example.
Releasing method:
Remove battery.
Ver. 1.1
Page of 24