ICD-UX502 - Sony Audio Service Manual (repair manual). Page 3

Read Sony ICD-UX502 Service Manual online

ICD-UX502
3
ABOUT  THE  BOARDS  REPLACING
When the boards installed in this unit are defective, exchange the 
complete mounted board.
However the microphone jack (J301) and headphone jack (J302) 
on the MAIN board are exchangeable. Refer to “4. EXPLODED 
VIEWS” (page 18).
ABOUT  THE  DESTINATION  SETTING  WHEN  REPLAC-
ING  THE  MAIN  BOARD
When the MAIN board of this unit is replaced, perform processing 
according to the following procedure.
Precaution
The contents which are not opened to customers are included 
in the following procedure. After you are cautious of handling of 
information, execute work under the suffi cient administration.
1.  About the preparing of tools
Download the tools used by this work from the homepage of TISS. 
When the tools cannot be confi rmed by TISS, confi rm to the ser-
vice headquarters.
2. Setting 
method
Note:
 The destination setting is impossible when battery voltage is not 
enough.
 
  Do work using the battery with suffi cient battery level.
Procedure:
1.  Equip this unit with battery.
2.  Connect this unit to the PC.
To USB port of PC
IC recorder
PC
3.  Unzip the model setting fi le to get folder on PC.
4.  Open the unzipped folder and choose the following folder.
 ICD_UX502_CE7
5. Copy 
the 
“DEVINFO.UPG” 
fi le included in the folder selected 
at step 4 to root folder of this unit.
6.  Remove this unit from the PC.
7.  “Updating” is displayed on the screen of this unit, and this unit 
is rebooted automatically.
8.  The destination setting is completed.
3. Confi rmation method
Procedure:
1.  Equip this unit with battery.
2.  Slide the [HOLD•POWER] switch in the direction of “POW-
ER” until the window display appears.
3.  Slide the [DPC (SPEED CTRL)] switch to OFF.
4.  While pressing the [STOP/
x
] and [VOL –] keys, slide the 
[DPC (SPEED CTRL)] switch to ON.
5.  The test mode menu is displayed, and enter the test mode. Re-
lease the [STOP/
x
] and [VOL –] keys.
6. Confi rm that the destination has been changed.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
<SERVICE MENU>
ICD-UX502/CE7
1.00.01
LCD Display
Destination
Model name
Firmware version
7.  Remove battery to release the test mode.